I-DBP-6673b
IJoytech / OEM
Ingcaciso yeMveliso | Uvavanyo lwegazi le-ECG | |
Imodeli | I-DBP- 6673b | |
Bonisa | Ubungakanani be-LCD Digital Shoprent: 95.5mm × 54.5mm (3.76 'x 2.15 ') | |
Indlela yokulinganisa | Indlela ye-OSChellometric | |
Uxinzelelo | Ukucinezelwa ngokuzenzekelayo | |
Uluhlu lokulinganisa lwe-BP | Uxinzelelo lwe-systolic | I-60 ~ 260mmhg |
Uxinzelelo lwedistolic | 40 ~ 200mhg | |
Pulse | I-30 ~ 180beats / umzuzu | |
Ukulungelelaniswa komgangatho we-BP | Ukuchaneka koXabiso | ± 3mmhg okanye ± 2% ngaphezulu kwe-200 mmhg |
Ukuchaneka | I-30 ~ 39beat / umzuzu ± 5bpm | |
I-40 ~ 180beats / umzuzu ± 5% | ||
Indlela yokulinganisa i-ECG | I-Ten-Channel Ecg | |
Uluhlu lokulinganisa lwe-ECG | bandwidth | 0.67 ~ 40hz |
Inqanaba lentliziyo | 30 ~ 199 Beats / umzuzu | |
Ixesha lokulinganisa | Imizuzwana engama-30 | |
Ukulungelelaniswa kwe-ECG | Inqanaba lentliziyo | ± 5% |
Imemori | I-2X150 BP ye-BP ngokwamaqela amabini ngomhla kunye nexesha Iinkumbulo ze-ECG20 ye-ECG ngamaqela amabini anamhla nexesha | |
Umsebenzi we-BP | Ukuhlolwa kwentliziyo engaqhelekanga | |
Ngoobani uphawu lokufundisa | ||
Uvavanyo lwe-3 lokugqibela | ||
Umsebenzi we-ECG | Isalathisi se-fibring | |
Isigqi esiqhelekileyo se-sinus, eBradyCardia, TachyCardia | ||
Omnye umsebenzi | Ukucima amandla okuzenzekelayo | |
Ukuchonga ibhetri | ||
Isibane esingasemva | ||
Umthombo wamandla | Iibhetri ze-AA AA | |
Ubomi bebhetri | Malunga neenyanga ezimbini kwiimvavanyo ezi-3 ngosuku | |
Ubunzima beyunithi | Malunga.549G (19.4 oz.) (Kubandakanya ibhetri) | |
Ubungakanani beyunithi | Malunga.142.5 x 107.2 x 44mm (5.61 'x 4.22 ' x 1.73 ') (L X W) | |
Inketho ye-cuff | Ihambelana nengalo ye-22cm ~ 36 cm Ijika iRhafu yengalo 22cm ~ 42 cm Ukujikeleza kwengalo 32 i-48 cm, khetha enye. | |
I-Electrode SPIT | ||
Indawo yokusebenza | Ubushushu | 10 ℃ ~ 40 ℃ (50 ℉ ~ 104 ℉) |
Umswakama | I-15% ~ 93% rh | |
Uxinzelelo | Uxinzelelo lwe-themospheric, 800hpa ~ 1060hpa | |
Indawo yokugcina | Iqondo lokushisa: | -25 ℃ ~ 55 ℃ (-13 ℉ ~ 131 ℉) |
Umswakama | ≤ 93% rh | |
ibluetooth | Rhoqo | 2.4gz (2400-2483.5mhz) |
Uhlobo lwe-eriyali | Yakhelwe i-enboard e-eriyali | |
Igunya lokuhambisa | Malunga ne-3DBM | |
Ukwahlulahlulwa: |
Izixhobo eziphakathi ngaphakathi, uhlobo lwe-bf | |
I-Ingress yokhuseleko lokhuseleko | I-IP21 I-Indoor isetyenziswa kuphela |
Inxalenye enye ebandakanya:
I-PC enye ye-ECG yokuhlola i-DBP-6673b,
Incwadana yemigaqo yomsebenzisi wesiNgesi
Enye i-pc yengalo ye-cuff
Ityala elinye lokugcina
Singumenzi ophambili ophambili olwenziweyo kwizixhobo zonyango lwezonyango ngaphezulu kweminyaka engama-20, egubungela I-infrared thermometer, I-Digital Artometers, Uxinzelelo lwegazi yedijithali ,Impompo yebele , I-Nebizer yezonyango, Pull ye-obimeter , kunye nemigca ye-PACT.
Iinkonzo ze-OEM / ze-ODM ziyafumaneka.
Zonke iimveliso zenziwe kwaye zenziwa ngaphakathi komzi-mveliso phantsi kwe-ISO 13485 kwaye ziqinisekisiwe ngo-CE MDR kwaye zidlulise i-US FDA, eCanada, i-Canada, fikelela, njl.
Ngo-2023, umzi-mveliso omtsha kaJoychch wabasebenza, ehlala ngaphezulu kwe-100,000 yendawo eyakhiwe. Iyonke i-260,000 inikezelwe kwi-R & D kunye nokuveliswa kwezixhobo zonyango lwasekhaya, inkampani ngoku iyaqhayisa ngemithombo yemveliso ezenzekelayo kunye neendawo zokugcina izinto.
Simkele ngokufudumeleyo bonke abathengi, yiyure enye kuphela ngololiwe onesikhawulezi ukusuka eShanghai.
IJoytech isebenza amaziko amathathu okuvelisa, eyendlu ngaphakathi, ukuxhasa amandla ethu emveliso yehlabathi.
UJoytech uthatha inxaxheba kwiimpawu ezingaphezulu kwe-10 zonqulo kunye nee-goding minyaka le, ebonisa ukuzibophelela kwethu ekufumaneni nabathengi kwiimarike zalo.
Isaziso soKhuseleko
Imiyalelo ebalulekileyo ngaphambi kokusetyenziswa
1. Sukudidanisa ngokwakho ukuze uzifumane. Imilinganiselo yoxinzelelo lwegazi kufuneka itolikwe kuphela yingcali yezempilo eqhelene nembali yakho yezonyango.
2. Nxibelelana nogqirha wakho ukuba iziphumo zovavanyo zihlala zibonisa ukufundwa okungaqhelekanga.
3. Ukuba uthatha amayeza, nxibelelana nogqirha wakho ukufumanisa ixesha elifanelekileyo lokulinganisa uxinzelelo lwegazi. Ungaze utshintshe amayeza amiselweyo ngaphandle kokubonisana kuqala nogqirha wakho.
4. Abantu abaneengxaki zokujikeleza kakhulu banokufumana ukungonwabi. Nxibelelana nogqirha wakho ngaphambi kokusebenzisa.
I-5. Yabantu abaneempawu ezingaqhelekanga okanye ukujikeleza okungazinzanga ezibangelwa sisifo seswekile, isifo esisibindi, i-Arteriosscarosis okanye ezinye iimeko zonyango, kusekho ukwahluka kwi-Wrist Ixabiso le-Wrist ngokuchasene nengalo ephezulu. Ukubeka iliso kwimikhwa kuxinzelelo lwegazi oluthathwe kwingalo okanye i-wrist iluncedo kwaye kubalulekile.
I-6. Abantu abanesifo se-vasocoction, isifo esisibindi okanye isifo seswekile, abasetyhini abanoxinzelelo lwabo ngaphambi kokulinganisa uxinzelelo lwegazi, amaxabiso ahlukeneyo anokufunyanwa ngenxa yemeko yabo.
7. Abantu abaphethwe yi-Ecreythmias anjenge-Adreal okanye i-bintricrilical bats okanye i-fibril ye-fibril okanye i-wibril ye-fibril kuphela isebenzisa kuphela lo msebenzi we-ECG ngokubonisana nogqirha wakho. Kwiimeko ezithile iindlela ze-Oscicicametric zinokuvelisa ukufundwa ngokuchanekileyo.
8. Imilinganiselo eqhubeka kakhulu inokubangela ukonzakala kwisigulana ngenxa yokuphazamiseka kwegazi.
9. I-Cuff akufuneki isetyenziswe ngaphezulu kwenxeba njengoko oku kunokubangela ukwenzakala okungaphezulu.
I-10. Sukufaka i-cuff ukuya kwilungu elisetyenziselwa ukungcola kwe-IV okanye nakuphi na ukufikelela kwi-intravascular, unyango okanye i-arterio-velous (AV) Shunt. Ukunyuka kwamaxabiso e-Cuff kunokuvimba ukuhamba kwegazi, kunokubangela ingozi kwisigulana.
11. I-cuff akufuneki ibekwe kwingalo ecaleni kwemastectomy. Kwimeko yemastectomy ephindwe kabini usebenzisa icala elincinci.
12. Ukucinezelwa kwe-Cuff kunokuphanga okwethutyana ukusebenza kwezixhobo zokubeka ngesweni kwangaxeshanye kwilungu elinye.
13. I-hose yoqhakamshelwano icinezelweyo inokubangela uxinzelelo oluqhubekayo lwe-Cuff olunokubangelwe kukuphazanyiswa kwegazi kunye nokwenzakala okuyingozi kwisigulana.
14. Jonga ukuba ukusebenza kweyunithi akukhokeli ekunciphiseni ixesha elide lokusasazeka kwesigulana.
15. Imveliso yenzelwe ukusetyenziswa kwayo kuphela. Sukusebenzisa kakubi nangayiphi na indlela.
16. Imveliso ayijongwa kwiintsana okanye abantu abangakwaziyo ukuveza iinjongo zabo.
17. Ixesha elide-ukunyuka kwamaxabiso eli-Bladder kunokubangela i-ecchymoma yengalo yakho.
18. Sukukwenza iyunithi okanye ingalo ye-cuff. Sukuzama ukulungisa.
19. Sebenzisa kuphela i-cuff evunyiweyo kule yunithi. Ukusetyenziswa kwezinye ii-cuffs ezingaqhelekanga kunokubangela iziphumo ezingachanekanga.
Imveliso engama-20.
21. Inkqubo inokuvelisa ukufundwa okungachanekanga ukuba igcinwe okanye isetyenziswe ngaphandle komenzi wobushushu obuchaziweyo kunye nobushushu obufumileyo.
22. UNGASISETYENZISI ISICWANGCISO NGOKUGQIBELA OKANYE IZIXHOBO ZE-ELKROMAGNETE eziveliswe ziiselfowuni okanye ezinye izixhobo, zinokubangela ukufundwa okungachanekanga kunye nokuphazamiseka okanye kube ngumthombo wokuphazamiseka kwisixhobo. Sukusebenzisa isixhobo ngexesha lesigulana esithuthi ngaphandle kwendawo yokhathalelo lwempilo yokuphazamiseka okukhoyo ngokunjalo.
23. Sukudibanisa iibhetri ezintsha nezindala ngaxeshanye
24. Guqula iibhetri xa isalathisi sebhetri esezantsi ' ' ivela kwiscreen. Faka indawo zombini iibhetri ngaxeshanye.
25. Sukudibanisa iintlobo zebhetri. Kucetyiswa iibhetri zeAlkaline.
26. Susa iibhetri kwisixhobo xa ungasebenzi ngaphezulu kweenyanga ezintathu.
27. Sukufaka iibhetri kunye nezibuko zabo zihambelana ngokuchanekileyo.
28. Ukulahla iibhetri ngokufanelekileyo; Gcina imithetho nemigaqo yendawo.
29. Musa ukuchukumisa i-electrode yale mveliso nakwabanye abaqhubi (kubandakanya ukwenziwa).
30. Ngexesha lomlinganiso we-ECG, ukuba ulusu lwakho okanye izandla zakho zomile kakhulu, nceda uqhubeke nethawula. Sebenzisa umlinganiso.
31. Xa umphezulu we-electrode ungcolile, nceda sula ngendwangu enamanzi okanye ikotoni yotywala, ubuncinci kube kanye ngenyanga.
32. Ngexesha lokulinganisa kwe-ECG, nceda ungasebenzisi imveliso ekubuyiseleni umkhombandlela ngezandla zakho zasekhohlo nasekunene.
33.Ukusebenza kwe-ECG ye-ECG ye-ECG SPHGMMOMAMEter kunokuchaphazeleka kubushushu obukhulu, umswakama kunye nokuphakathi.
34. Ukucebisa nge-Operator ukuba incwadana yemiyalelo / incwadana)
35Ixesha lokufudumala ifowuni ukuba ifudumeze kubushushu bokugcina ubuncinci (-25 ° C) phakathi kokusetyenziswa de isixhobo silungele ukusetyenziswa kumaqondo aphantsi kwe-20 ° C: malunga neeyure ezi-2.
36.Umntu ofunekayo kwifowuni ukuba ipholile ukusuka kubushushu bokugcina obukhulu (i-70 ° C) de isixhobo silungele ukusetyenziswa kumaqondo obushushu afanelekileyo (i-20 ° C): malunga neeyure ezi-2
Ingcaciso yeMveliso | Uvavanyo lwegazi le-ECG | |
Imodeli | I-DBP- 6673b | |
Bonisa | Ubungakanani be-LCD Digital Shoprent: 95.5mm × 54.5mm (3.76 'x 2.15 ') | |
Indlela yokulinganisa | Indlela ye-OSChellometric | |
Uxinzelelo | Ukucinezelwa ngokuzenzekelayo | |
Uluhlu lokulinganisa lwe-BP | Uxinzelelo lwe-systolic | I-60 ~ 260mmhg |
Uxinzelelo lwedistolic | 40 ~ 200mhg | |
Pulse | I-30 ~ 180beats / umzuzu | |
Ukulungelelaniswa komgangatho we-BP | Ukuchaneka koXabiso | ± 3mmhg okanye ± 2% ngaphezulu kwe-200 mmhg |
Ukuchaneka | I-30 ~ 39beat / umzuzu ± 5bpm | |
I-40 ~ 180beats / umzuzu ± 5% | ||
Indlela yokulinganisa i-ECG | I-Ten-Channel Ecg | |
Uluhlu lokulinganisa lwe-ECG | bandwidth | 0.67 ~ 40hz |
Inqanaba lentliziyo | 30 ~ 199 Beats / umzuzu | |
Ixesha lokulinganisa | Imizuzwana engama-30 | |
Ukulungelelaniswa kwe-ECG | Inqanaba lentliziyo | ± 5% |
Imemori | I-2X150 BP ye-BP ngokwamaqela amabini ngomhla kunye nexesha Iinkumbulo ze-ECG20 ye-ECG ngamaqela amabini anamhla nexesha | |
Umsebenzi we-BP | Ukuhlolwa kwentliziyo engaqhelekanga | |
Ngoobani uphawu lokufundisa | ||
Uvavanyo lwe-3 lokugqibela | ||
Umsebenzi we-ECG | Isalathisi se-fibring | |
Isigqi esiqhelekileyo se-sinus, eBradyCardia, TachyCardia | ||
Omnye umsebenzi | Ukucima amandla okuzenzekelayo | |
Ukuchonga ibhetri | ||
Isibane esingasemva | ||
Umthombo wamandla | Iibhetri ze-AA AA | |
Ubomi bebhetri | Malunga neenyanga ezimbini kwiimvavanyo ezi-3 ngosuku | |
Ubunzima beyunithi | Malunga.549G (19.4 oz.) (Kubandakanya ibhetri) | |
Ubungakanani beyunithi | Malunga.142.5 x 107.2 x 44mm (5.61 'x 4.22 ' x 1.73 ') (L X W) | |
Inketho ye-cuff | Ihambelana nengalo ye-22cm ~ 36 cm Ijika iRhafu yengalo 22cm ~ 42 cm Ukujikeleza kwengalo 32 i-48 cm, khetha enye. | |
I-Electrode SPIT | ||
Indawo yokusebenza | Ubushushu | 10 ℃ ~ 40 ℃ (50 ℉ ~ 104 ℉) |
Umswakama | I-15% ~ 93% rh | |
Uxinzelelo | Uxinzelelo lwe-themospheric, 800hpa ~ 1060hpa | |
Indawo yokugcina | Iqondo lokushisa: | -25 ℃ ~ 55 ℃ (-13 ℉ ~ 131 ℉) |
Umswakama | ≤ 93% rh | |
ibluetooth | Rhoqo | 2.4gz (2400-2483.5mhz) |
Uhlobo lwe-eriyali | Yakhelwe i-enboard e-eriyali | |
Igunya lokuhambisa | Malunga ne-3DBM | |
Ukwahlulahlulwa: |
Izixhobo eziphakathi ngaphakathi, uhlobo lwe-bf | |
I-Ingress yokhuseleko lokhuseleko | I-IP21 I-Indoor isebenzisa kuphela |
Inxalenye enye ebandakanya:
I-PC enye ye-ECG yokuhlola i-DBP-6673b,
Incwadana yemigaqo yomsebenzisi wesiNgesi
Enye i-pc yengalo ye-cuff
Ityala elinye lokugcina
Singumenzi ophambili ophambili olwenziweyo kwizixhobo zonyango lwezonyango ngaphezulu kweminyaka engama-20, egubungela I-infrared thermometer, I-Digital Artometers, Uxinzelelo lwegazi yedijithali ,Impompo yebele , I-Nebizer yezonyango, Pull ye-obimeter , kunye nemigca ye-PACT.
Iinkonzo ze-OEM / ze-ODM ziyafumaneka.
Zonke iimveliso zenziwe kwaye zenziwa ngaphakathi komzi-mveliso phantsi kwe-ISO 13485 kwaye ziqinisekisiwe ngo-CE MDR kwaye zidlulise i-US FDA, eCanada, i-Canada, fikelela, njl.
Ngo-2023, umzi-mveliso omtsha kaJoychch wabasebenza, ehlala ngaphezulu kwe-100,000 yendawo eyakhiwe. Iyonke i-260,000 inikezelwe kwi-R & D kunye nokuveliswa kwezixhobo zonyango lwasekhaya, inkampani ngoku iyaqhayisa ngemithombo yemveliso ezenzekelayo kunye neendawo zokugcina izinto.
Simkele ngokufudumeleyo bonke abathengi, yiyure enye kuphela ngololiwe onesikhawulezi ukusuka eShanghai.
IJoytech isebenza amaziko amathathu okuvelisa, eyendlu ngaphakathi, ukuxhasa amandla ethu emveliso yehlabathi.
UJoytech uthatha inxaxheba kwiimpawu ezingaphezulu kwe-10 zonqulo kunye nee-goding minyaka le, ebonisa ukuzibophelela kwethu ekufumaneni nabathengi kwiimarike zalo.
Isaziso soKhuseleko
Imiyalelo ebalulekileyo ngaphambi kokusetyenziswa
1. Sukudidanisa ngokwakho ukuze uzifumane. Imilinganiselo yoxinzelelo lwegazi kufuneka itolikwe kuphela yingcali yezempilo eqhelene nembali yakho yezonyango.
2. Nxibelelana nogqirha wakho ukuba iziphumo zovavanyo zihlala zibonisa ukufundwa okungaqhelekanga.
3. Ukuba uthatha amayeza, nxibelelana nogqirha wakho ukufumanisa ixesha elifanelekileyo lokulinganisa uxinzelelo lwegazi. Ungaze utshintshe amayeza amiselweyo ngaphandle kokubonisana kuqala nogqirha wakho.
4. Abantu abaneengxaki zokujikeleza kakhulu banokufumana ukungonwabi. Nxibelelana nogqirha wakho ngaphambi kokusebenzisa.
I-5. Yabantu abaneempawu ezingaqhelekanga okanye ukujikeleza okungazinzanga ezibangelwa sisifo seswekile, isifo esisibindi, i-Arteriosscarosis okanye ezinye iimeko zonyango, kusekho ukwahluka kwi-Wrist Ixabiso le-Wrist ngokuchasene nengalo ephezulu. Ukubeka iliso kwimikhwa kuxinzelelo lwegazi oluthathwe kwingalo okanye i-wrist iluncedo kwaye kubalulekile.
I-6. Abantu abanesifo se-vasocoction, isifo esisibindi okanye isifo seswekile, abasetyhini abanoxinzelelo lwabo ngaphambi kokulinganisa uxinzelelo lwegazi, amaxabiso ahlukeneyo anokufunyanwa ngenxa yemeko yabo.
7. Abantu abaphethwe yi-Ecreythmias anjenge-Adreal okanye i-bintricrilical bats okanye i-fibril ye-fibril okanye i-wibril ye-fibril kuphela isebenzisa kuphela lo msebenzi we-ECG ngokubonisana nogqirha wakho. Kwiimeko ezithile iindlela ze-Oscicicametric zinokuvelisa ukufundwa ngokuchanekileyo.
8. Imilinganiselo eqhubeka kakhulu inokubangela ukonzakala kwisigulana ngenxa yokuphazamiseka kwegazi.
9. I-Cuff akufuneki isetyenziswe ngaphezulu kwenxeba njengoko oku kunokubangela ukwenzakala okungaphezulu.
I-10. Sukufaka i-cuff ukuya kwilungu elisetyenziselwa ukungcola kwe-IV okanye nakuphi na ukufikelela kwi-intravascular, unyango okanye i-arterio-velous (AV) Shunt. Ukunyuka kwamaxabiso e-Cuff kunokuvimba ukuhamba kwegazi, kunokubangela ingozi kwisigulana.
11. I-cuff akufuneki ibekwe kwingalo ecaleni kwemastectomy. Kwimeko yemastectomy ephindwe kabini usebenzisa icala elincinci.
12. Ukucinezelwa kwe-Cuff kunokuphanga okwethutyana ukusebenza kwezixhobo zokubeka ngesweni kwangaxeshanye kwilungu elinye.
13. I-hose yoqhakamshelwano icinezelweyo inokubangela uxinzelelo oluqhubekayo lwe-Cuff olunokubangelwe kukuphazanyiswa kwegazi kunye nokwenzakala okuyingozi kwisigulana.
14. Jonga ukuba ukusebenza kweyunithi akukhokeli ekunciphiseni ixesha elide lokusasazeka kwesigulana.
15. Imveliso yenzelwe ukusetyenziswa kwayo kuphela. Sukusebenzisa kakubi nangayiphi na indlela.
16. Imveliso ayijongwa kwiintsana okanye abantu abangakwaziyo ukuveza iinjongo zabo.
17. Ixesha elide-ukunyuka kwamaxabiso eli-Bladder kunokubangela i-ecchymoma yengalo yakho.
18. Sukukwenza iyunithi okanye ingalo ye-cuff. Sukuzama ukulungisa.
19. Sebenzisa kuphela i-cuff evunyiweyo kule yunithi. Ukusetyenziswa kwezinye ii-cuffs ezingaqhelekanga kunokubangela iziphumo ezingachanekanga.
Imveliso engama-20.
21. Inkqubo inokuvelisa ukufundwa okungachanekanga ukuba igcinwe okanye isetyenziswe ngaphandle komenzi wobushushu obuchaziweyo kunye nobushushu obufumileyo.
22. UNGASISETYENZISI ISICWANGCISO NGOKUGQIBELA OKANYE IZIXHOBO ZE-ELKROMAGNETE eziveliswe ziiselfowuni okanye ezinye izixhobo, zinokubangela ukufundwa okungachanekanga kunye nokuphazamiseka okanye kube ngumthombo wokuphazamiseka kwisixhobo. Sukusebenzisa isixhobo ngexesha lesigulana esithuthi ngaphandle kwendawo yokhathalelo lwempilo yokuphazamiseka okukhoyo ngokunjalo.
23. Sukudibanisa iibhetri ezintsha nezindala ngaxeshanye
24. Guqula iibhetri xa isalathisi sebhetri esezantsi ' ' ivela kwiscreen. Faka indawo zombini iibhetri ngaxeshanye.
25. Sukudibanisa iintlobo zebhetri. Kucetyiswa iibhetri zeAlkaline.
26. Susa iibhetri kwisixhobo xa ungasebenzi ngaphezulu kweenyanga ezintathu.
27. Sukufaka iibhetri kunye nezibuko zabo zihambelana ngokuchanekileyo.
28. Ukulahla iibhetri ngokufanelekileyo; Gcina imithetho nemigaqo yendawo.
29. Musa ukuchukumisa i-electrode yale mveliso nakwabanye abaqhubi (kubandakanya ukwenziwa).
30. Ngexesha lomlinganiso we-ECG, ukuba ulusu lwakho okanye izandla zakho zomile kakhulu, nceda uqhubeke nethawula. Sebenzisa umlinganiso.
31. Xa umphezulu we-electrode ungcolile, nceda sula ngendwangu enamanzi okanye ikotoni yotywala, ubuncinci kube kanye ngenyanga.
32. Ngexesha lokulinganisa kwe-ECG, nceda ungasebenzisi imveliso ekubuyiseleni umkhombandlela ngezandla zakho zasekhohlo nasekunene.
33.Ukusebenza kwe-ECG ye-ECG ye-ECG SPHGMMOMAMEter kunokuchaphazeleka kubushushu obukhulu, umswakama kunye nokuphakathi.
34. Ukucebisa nge-Operator ukuba incwadana yemiyalelo / incwadana)
35Ixesha lokufudumala ifowuni ukuba ifudumeze kubushushu bokugcina ubuncinci (-25 ° C) phakathi kokusetyenziswa de isixhobo silungele ukusetyenziswa kumaqondo aphantsi kwe-20 ° C: malunga neeyure ezi-2.
36.Umntu ofunekayo kwifowuni ukuba ipholile ukusuka kubushushu bokugcina obukhulu (i-70 ° C) de isixhobo silungele ukusetyenziswa kumaqondo obushushu afanelekileyo (i-20 ° C): malunga neeyure ezi-2