XM-111
Joytech / OEM
The XM-111 Fingertip Pulse Oximeter is a compact, lightweight, and energy-efficient device designed to provide fast and accurate monitoring of blood oxygen saturation (SpO₂), pulse rate (PR), perfusion index (PI), and waveform.
With its simple one-button operation and portable design, it is convenient for daily health checks at home or while traveling.
Equipped with five display modes and adjustable brightness levels (1–5), the XM-111 ensures clear and flexible readings in different environments.
Its intuitive interface shows pulse bar graphs and waveform displays, making it easier for users to understand real-time cardiovascular conditions.
The device features a visual low-voltage warning to remind users when battery power is insufficient. It also includes an auto power-off function, shutting down automatically within 10 seconds when "Finger out" is detected, helping to conserve energy.
For added functionality, the XM-111 is designed with a beep and reminder system: when activated, the screen will flash and the buzzer will sound in response to alerts.
Reliable, portable, and easy to use, the XM-111 is an excellent choice for effective home health monitoring and personal wellness management.
Beep and tips
Automatic power-off
Light weight and easy to carry
Adjustable brightness, 5 display modes
Intelligent power saving design, 2 "AAA" batteries
Dual color display, 360° rotatable view
Model | XM-111 |
Type | Fingertip pulse oximeter |
Measurement Method | Transmission-type |
Display Type | Dual-color display |
SpO2 Display Range | 0%-100% |
SpO2 Measurement Range | 70%-100% |
Pulse Rate Display Range | 0-240bpm |
Pulse Rate Measurement Range | 30-240bpm |
Running Conditions | 5-40℃ |
Display Size | 0.96 inch |
Humidity | 15%-93%RH |
Pressure | 700hPa-1060hPa |
SpO2 | Yes |
Pulse Rate | Yes |
Adjustable Brightness | Yes |
Display Modes | 5 |
Automatic Power-off | Yes |
Beeps | Yes |
Low Oxygen Content | Yes |
Bluetooth | Optional |
Power Source | 2“AAA”batteries |
Finger off Remind | Yes |
Power Dissipation | < 60mA |
The Data UPDATE Period | < 12S |
RED | Approx. 660nm Approx. 3.2mW |
IR | Approx. 905nm Approx. 2.4mW |
Unit Dimension | 60.2x35x35.5mm |
Unit Weight | Approx. 54g |
Packing | 1 pc / Gift box; 60 pcs / Carton |
Carton Dimensions | 36x22.5x35cm |
Carton Weight(G.W.) | 6.7kg |
• 24 years of OEM & ODM expertise.
• 3 manufacturing centers with 260,000㎡ automated facilities and 2000㎡ automated warehouses.
• 30+ production lines & 100+ patented innovations.
• ISO 13485, MDSAP, BSCI certified quality systems.
• Full customization for global brands, including Fortune 500 partners.

• WHX Dubai (formerly Arab Health), Dubai
• WHX Miami (formerly FIME), Miami, USA
• Hong Kong Electronics Fair, Hong Kong
• ABC Kids Expo, USA
• KIMES, Seoul, Korea
• MEDITEX Bangladesh, Dhaka
• Hospitalar, São Paulo, Brazil
• Canton Fair, China
• MEDICA, Düsseldorf, Germany
We are committed to meeting partners worldwide at leading international medical and consumer health exhibitions.

Q: What makes the adjustable display features practical?
A: The 360° rotatable screen lets you easily view readings from any angle. Combined with 5 adjustable brightness levels, it ensures clear visibility in various lighting conditions, day or night.
Q: Is this designed for occasional spot-checks or regular monitoring?
A: With its detailed waveform and perfusion index display, it is suitable for both. The intuitive interface provides deeper insights for regular tracking, while its one-button operation keeps it simple for quick daily checks.
Q: What are the key advantages of this model for home use?
A: It combines hospital-grade accuracy with exceptional ease of use. The large, rotatable dual-color display, multiple viewing modes, and automatic features make it reliable and user-friendly for everyday health awareness.
For customized solutions or partnership inquiries, please contact us at marketing@sejoygroup.com to discuss your specific needs.
1. Before use, carefully read the manual.
2. Do not use the pulse oximeter:
-If you are allergic to rubber products.
-If the device or finger is damp.
-During MRI or CT scan.
-While taking a blood pressure measurement on the arm.
-Nail polish, dirty, coating fingers and false nails applied fingers.
-Fingers with anatomical changes, edemas, scars or burns.
-Too big finger: the width of finger is over than 20mm and the thickness is over than 15mm.
-Too small finger: the width of finger is less than 10mm and the thickness is less than 5mm.
-Minors under 18 years old.
-The environmental light changes strongly.
-Near flammable or explosive gas mixtures.
3. Extended use may cause pain for people with circulatory disorders. Do not use the pulse oximeter for longer than two hours on one finger.
4. Measurements are for your information only - they are no substitute for a medical examination. If an unexpected reading occurs, the operator can take several more measurements and consult a doctor.
5. Check the pulse oximeter regularly before use to ensure that there is no visible damage and the batteries are still sufficiently charged. In case of doubt, do not use the device and contact customer services or authorized retailer.
6. Do not use any additional parts that are not recommended by the manufacturer.
7. Any circumstances do not open or repair the device by yourself. Failure to comply will result in voiding of the warranty. For repairs, please contact customer services or authorized retailer.
8. Do not look directly inside the housing during the measurement. The red light and the invisible infrared light in the pulse oximeter are harmful to your eyes.
9. This device is not intended for use by people (including children) with restricted physical, sensory or mental skills or a lack of experience or a lack of knowledge, unless they are supervised by a person who has responsibility for their safety or they receive instructions from this person on how to use the device. Children should be supervised around the device to ensure they do not play with it.
10. If the unit has been stored at temperatures below 0℃, leave it in a warm place for about two hours before using it.
11. If the unit has been stored at temperatures above 40 , leave it in a cool place for about two hours before using it.
12. The displays for the pulse bar does not allow the strength of the pulse or circulation to be evaluated at the measurement site. Rather, they are exclusively used to display the current visual signal variation at the measurement site and do not enable diagnostics for the pulse.
13. Operation of the fingertip pulse oximeter may be affected by the use of an electrosurgical unit (ESU).
14. Follow local ordinances and recycling instructions regarding disposal or recycling or the device and device components, including batteries.
15. This equipment complies with IEC 60601-1-2 for electromagnetic compatibility for medical electrical equipment and systems. In healthcare center or other environment, their radio transmission equipment and electromagnetic interference may affect the performance of the oximeter.
16. This equipment is not intended for use during patient transport outside the healthcare facility.
17. When the signal is not stable, the reading may inaccurate. Please do not reference.
18. Portable and mobile RF communications equipment can affect medical electrical equipment.
19. WARNING: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
20. WARNING: PORTABLE RF communications equipment (includeing peripherals such as antenna cables and external antennas) should be used no closer than 30cm (12 inches) to any part of Fingertip Pulse Oximeter, including cables specified by the MANUFACTURER. Otherwise, degradation of the performance of this equipment could result.
21. Any serious incident that has occurred in relation to the device should be reported to the manufacture and the competent authority of the Member State in which the user and/or patient is established.