Availability: | |
---|---|
NB-1101
OEM available
1 Introduction
Intended use/Indications for use:
The Compressor Nebulizer include air compressor that provide a source of compressed air with a jet (Pneumatic) nebulizer to convert certain inhalable drugs into an aerosol form for inhalation by a patient. The device can be used with adult or pediatric patients(2 years and older) in the home, hospital, and sub-acute settings.
Name of disease or condition:
Asthma, Chronic obstructive pulmonary disease (COPD),Cystic fibrosis, Respiratory tract
infection, etc disease of respiratory system.
Patient population:
adults or children (2 years and older)
Intended user:
healthcare person or lay person
2 Safety Instructions
Cautions
1. The product should never be left unattended when plugged in.
2. The patient is an intended operator, close supervision is necessary when this product is used by, or near children or disabled individuals.
3. Operate the device only as intended. Do not use the device for any other purpose
4. Always ensure that the air vents are not blocked or obstructed in any way.
5. Do not disassemble the nebulizer or attempt to repair it; any attempt for repair should be completed only by qualified technical personnel.
Warning
1. The nebulizer can work with the solution or suspensions only, but not with emulsions or high viscosity drugs.
2.Operate the device only as intended. Do not use the nebulizer for any other purpose or in a manner inconsistent with these instructions.
3.For type, dose, and regime of medication follow the instructions of your physician or licensed healthcare practitioner.
4.Never use any liquid in the nebulizer other than those prescribed by your doctor. Liquids such as cough medicines or essential oils can harm both the machine and the patient.
3 Technical Data
SPECIFICSTIONS | |
Model: | NB-1101 |
Type: | Compressor Nebulizer |
Power supply: | AC 230V, 50 Hz |
Input Power: | ≤ 80VA |
Operating Mode: | Continuous Operation |
Sound Level: | ≤ 65dB(A) |
Gas Flow Volume Rate: | ≥6.5L/min |
Dimensions: | Approx. 6.7" (w) × 5.7" (h) × 4.6" (d) (170.2 mm × 144.4 mm × 117.9 mm) |
Weight: | Approx. 1.24kg (Compressor only) |
Operating Temperature/Humidity/ Atmospheric Pressure | +5°C to +40°C (+41°F to +104°F)/15% to 90% RH/86 kPa to 106 kPa |
Storage and Transport Temperature/Humidity/ Atmospheric Pressure | –20°C to +55°C (–4°F to +131°F)/5% to 93% RH/70 kPa to 106 kPa |
Normal Working Pressure: | 50kPa~180kPa |
Abnormal Working Pressure: | 190kPa~320kPa |
Classification: | Class II equipment, Type BF applied part |
Contents: | 1 Compressor nebulizer unit, 5 Air Filters, 1 Owner’s manual |
The Standard Accessories: | Air filter(×5 pcs) |
Applied Parts: | Mask, Mouthpiece |
Accessible Parts: | Shell of Compressor |
Fuses: | 5JF 1.6AL 250V |
1. Large amount of fog, saving time
2. Fine atomization, easily absorbed
3. One button operation, easy to use
4. Super long Air duct, free movement
5. Low residue and high utilization rate
6. Creates a low noise inhalation environment
7. Double suction mode of mask and suction nozzle
1 Introduction
Intended use/Indications for use:
The Compressor Nebulizer include air compressor that provide a source of compressed air with a jet (Pneumatic) nebulizer to convert certain inhalable drugs into an aerosol form for inhalation by a patient. The device can be used with adult or pediatric patients(2 years and older) in the home, hospital, and sub-acute settings.
Name of disease or condition:
Asthma, Chronic obstructive pulmonary disease (COPD),Cystic fibrosis, Respiratory tract
infection, etc disease of respiratory system.
Patient population:
adults or children (2 years and older)
Intended user:
healthcare person or lay person
2 Safety Instructions
Cautions
1. The product should never be left unattended when plugged in.
2. The patient is an intended operator, close supervision is necessary when this product is used by, or near children or disabled individuals.
3. Operate the device only as intended. Do not use the device for any other purpose
4. Always ensure that the air vents are not blocked or obstructed in any way.
5. Do not disassemble the nebulizer or attempt to repair it; any attempt for repair should be completed only by qualified technical personnel.
Warning
1. The nebulizer can work with the solution or suspensions only, but not with emulsions or high viscosity drugs.
2.Operate the device only as intended. Do not use the nebulizer for any other purpose or in a manner inconsistent with these instructions.
3.For type, dose, and regime of medication follow the instructions of your physician or licensed healthcare practitioner.
4.Never use any liquid in the nebulizer other than those prescribed by your doctor. Liquids such as cough medicines or essential oils can harm both the machine and the patient.
3 Technical Data
SPECIFICSTIONS | |
Model: | NB-1101 |
Type: | Compressor Nebulizer |
Power supply: | AC 230V, 50 Hz |
Input Power: | ≤ 80VA |
Operating Mode: | Continuous Operation |
Sound Level: | ≤ 65dB(A) |
Gas Flow Volume Rate: | ≥6.5L/min |
Dimensions: | Approx. 6.7" (w) × 5.7" (h) × 4.6" (d) (170.2 mm × 144.4 mm × 117.9 mm) |
Weight: | Approx. 1.24kg (Compressor only) |
Operating Temperature/Humidity/ Atmospheric Pressure | +5°C to +40°C (+41°F to +104°F)/15% to 90% RH/86 kPa to 106 kPa |
Storage and Transport Temperature/Humidity/ Atmospheric Pressure | –20°C to +55°C (–4°F to +131°F)/5% to 93% RH/70 kPa to 106 kPa |
Normal Working Pressure: | 50kPa~180kPa |
Abnormal Working Pressure: | 190kPa~320kPa |
Classification: | Class II equipment, Type BF applied part |
Contents: | 1 Compressor nebulizer unit, 5 Air Filters, 1 Owner’s manual |
The Standard Accessories: | Air filter(×5 pcs) |
Applied Parts: | Mask, Mouthpiece |
Accessible Parts: | Shell of Compressor |
Fuses: | 5JF 1.6AL 250V |
1. Large amount of fog, saving time
2. Fine atomization, easily absorbed
3. One button operation, easy to use
4. Super long Air duct, free movement
5. Low residue and high utilization rate
6. Creates a low noise inhalation environment
7. Double suction mode of mask and suction nozzle