| Unit Dimension: | |
|---|---|
| Power Source: | |
| Nature of Business: | |
| Service Offering: | |
| Availability: | |
NB-1206
Joytech / OEM
The NB-1206 Compressor Nebulizer is powered by an advanced lithium-ion battery system, bringing exceptional portability and reliability to respiratory therapy.
Designed with high energy density, the battery stores more power within a compact size, ensuring longer operation time per charge.
Its lightweight construction makes the device easy to carry, while the long cycle life of the battery guarantees hundreds to thousands of charge-discharge cycles, reducing replacement costs and improving overall durability.
In addition, the low self-discharge rate of the lithium-ion battery allows the NB-1206 to retain its charge when not in use, making it particularly convenient for users who require occasional therapy or keep it for emergency purposes.
With these advantages, the NB-1206 is not only reliable for daily home treatment but also highly suitable for outdoor use, travel, or urgent situations where no direct power supply is available.
Combined with safe materials and a stable compressor design, it provides efficient aerosol delivery while ensuring user comfort and peace of mind.
Large amount of fog, saving time
Fine atomization, easily absorbed
Adjustable nebulization rate
Nebulizer kit holder
Clear light indicator
Easy to use, one-button operation
Lithium-ion battery-powered optional
Portable, compact, easy to carry
Complete with accessories
Replaceable air filter
DC power supply
Model | NB-1206 |
Type | Compressor |
Power resource | Type C |
Lithium-ion battery-powered | Optional |
Power Supply | DC5V |
On-off Mode | Mechanical Boat-type Switch |
Power Consumption | ≤10VA |
Fuse | No |
Nebulization Rate | ≥0.2mL/min |
Residual Volume | ≤1.0mL |
Noise | ≤60dB(A) |
Gas Flow Volume Rate | ≥5L/min |
Particle Size (MMAD) | 3.5μm±25% |
Accessory Storage | No |
Power Cord Storage | No |
Power-on Indicator | Yes |
Light Indicator | Green/Orange |
Nebulization Timing | No |
Beeper | No |
Operating Environment | Temperature: 5°C~40°C, Humidity: 15%RH~90%RH . Pressure: 86kPa to 106kPa |
Storage Environment | Temperature: –20°C ~+55°C, Humidity: 5%~93% RH, Pressure: 70 kPa to 106 kPa |
Unit Dimension | 13.0 x 8.0 x 5.9cm |
Unit Weight | Approx. 215g |
• 24 years of OEM & ODM expertise.
• 3 manufacturing centers with 260,000㎡ automated facilities and 2000㎡ automated warehouses.
• 30+ production lines & 100+ patented innovations.
• ISO 13485, MDSAP, BSCI certified quality systems.
• Full customization for global brands, including Fortune 500 partners.

• WHX Dubai (formerly Arab Health), Dubai
• WHX Miami (formerly FIME), Miami, USA
• Hong Kong Electronics Fair, Hong Kong
• ABC Kids Expo, USA
• KIMES, Seoul, Korea
• MEDITEX Bangladesh, Dhaka
• Hospitalar, São Paulo, Brazil
• Canton Fair, China
• MEDICA, Düsseldorf, Germany
We are committed to meeting partners worldwide at leading international medical and consumer health exhibitions.

Q: How long can the nebulizer operate on a single battery charge?
A: The high-energy-density lithium-ion battery provides extended operation per charge, supporting multiple therapy sessions. Specific duration depends on the selected nebulization rate, but it is designed for reliable daily or travel use without frequent recharging.
Q: Is it easy to maintain and clean for regular use?
A: Yes. It includes a complete set of accessories and features a replaceable air filter. The main unit and nebulizer kit can be easily disassembled for cleaning, ensuring hygiene and consistent performance.
Q: Who would benefit most from this battery-powered model?
A: It is ideal for active individuals, frequent travelers, or families who need a reliable, cord-free solution for respiratory therapy at home, outdoors, or in situations without immediate access to a power outlet.
For customized solutions or partnership inquiries, please contact us at marketing@sejoygroup.com to discuss your specific needs.
1.1 Intended purpose
The Compressor Nebulizer include air compressor that provide a source of compressed air with a jet (Pneumatic) nebulizer to convert certain inhalable drugs into an aerosol form for inhalation by a patient.
1.2 Indications for use
The Compressor Nebulizer include air compressor that provide a source of compressed air with a jet (Pneumatic) nebulizer to convert certain inhalable drugs into an aerosol form for inhalation by a patient. The device can be used with adult or pediatric patients (2 years and older) in the home, hospital, and sub-acute settings.
2. Contraindications
None
3. Indications
Asthma, Chronic obstructive pulmonary disease (COPD), Cystic fibrosis, Respiratory tract infection, etc disease of respiratory system.
4. Intended patient population
4.1 Intended patient
Adults or children (2 years and older)
4.2 Expected user
Healthcare person or lay person (Children under 12 years old need to use under adult supervision)
5. Warning
1) This product is not a toy, please do not allow children to play with it.
2) Please seek medical attention immediately, if you have any allergic reaction.
3) The nebulizer can work with the solution or suspensions only, but not with emulsions or high viscosity drugs.
4) Operate the device only as intended. Do not use the nebulizer for any other purpose or in a manner inconsistent with these instructions.
5) For type, dose, and regime of medication follow the instructions of your physician or licensed healthcare practitioner.
6) Never use any liquid in the nebulizer other than those prescribed by your doctor. Liquids such as cough medicines or essential oils can harm both the machine and the patient.
7) Do not immerse the compressor in liquid and do not use while bathing. If the unit falls into water, don't touch the device unless it is unplugged, otherwise there is a risk of electric shock.
8) Do not use the unit if it has been dropped, exposed to extreme temperatures or high humidity or damaged in any way.
9) Keep the device and kids accessories out of reach of unsupervised infants and children. The device may contain small accessories that may post a choking hazard.
10) Do not use in anaesthetic or ventilator breathing circuits.
11) Never use while sleeping or drowsy.
12) Not suitable for use in the presence of flammable anesthetic mixture with air or oxygen or nitrous oxide.
13) Do not operate the device where oxygen is being administered in a closed environment.
14) Do not crease or fold the air tube.
15) Close supervision is necessary when this product is used by, on, or near children over 2 years of age or disabled individuals.
16) Please stop using the device immediately if the nebulizer is not working properly like: when it makes unusual sounds, or if you feel pain or discomfort while using.
17) Do not expose the unit to direct sunlight, heated or hot surfaces, humid environments, extreme temperatures, strong static electricity or electroma- gnetic waves. Be sure to use the device at a place where the power plug is easily accessible during treatment.
18) Keep quiet and relax during the treatment process, and avoid moving or talking.
19) Use of accessories or detachable parts other than those specified by the manufacturer may result in unsafe or degraded performance.
20) Please do not connect other parts not recommended by the manufacturer to the atomizer to avoid unnecessary wrong connection.
21) Please away from children to prevent strangulation due to cables and hoses.
22) Do not use the compressor (main unit) or power cord while they are wet.
23) Do not use when bathing or with wet hands.
24) Do not touch the main unit for other than necessary operation such as turning off the power while nebulizing.
25) Do not operate the device with a damaged power cord or plug.
26) Unplug the power cord from the electrical outlet before cleaning the device.
27) If the power cord is damaged or in other circumstances, and need to replace the power cord, contact the professional personnel of the manufacturer. Do not replace the power cord yourself.
28) Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
29) PORTABLE RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm(12 inches) to any part of the Compressor Nebulizer, including cab is specified by the manufacture. Otherwise, degradation of the performance of this equipment could result.
30) Never immerse the unit in water to clean as it may damage the unit.
31) Do not place or attempt to dry the device, components or any of the nebulizer parts in a microwave oven.
32) This product should not be used by patients, who are unconsciousor are not breathing spontaneously.