Availability: | |
---|---|
NK-101
Joytech / OEM
Intended Purpose: The nebulizer kit is intended to aerosolize medication for inhalation therapy.
Indications for use: The nebulizer kit is intended to aerosolize medication for inhalation by a patient in the hospital, clinic or home care environment. And the patient include all patients except for premature neonate and newborns.The nebulizer is a single patient use device.
Contraindications:None
Indications
Asthma, Chronic obstructive pulmonary disease (COPD),Cystic fibrosis, Respiratory tract infection, etc disease of respiratory system.
Intended patient: Adult, child and infant.
Warning/cautions
1)The product is strictly prohibited to use after the service life.
2)Keep the nebulizer kit out of reach of unsupervised infants and children. The device may contain small accessories that may post a choking hazard.
3)Children, infants, ally ill person or those without self-awareness shall not be used without adult supervision.
4)For the type, dose and regime of medication please follow follow the doctor's advice.
5)The coma and thick sputum patients should follow the doctor's advice.
6)The solution of the medication cup should not exceed the maximum amount of solution marked by the cup body of the liquid cup, otherwise the nebulization effect will be affected.
7)Use Population: patients with respiratory disease or syndrome, patients with asthma, chronic bronchitis, upper respiratory tract infection, chronic obstructive pulmonary disease, and other lung diseases.
8)If there are wounds on the area where the mask is used, protective measures should be taken in advance.
9)The use of high concentration of liquid medicine for atomization may block the airflow nozzle, leading to No nebulization or low nebulization rate.
10)The Nebulizer is not available for the respiratory anesthesia system and the ventilator system.
11)Can be connected to compressed air supply for nebulization.
12)Compressed air is recommended as a drive in COPD patients and elderly patients with pulmonary insufficiency.
13)The size of the nebulization rate is related to the flow of air, please pay attention to adjust! The recommended compressed air is 4-8 L/min.
14)Do not place or carry nebulizers containing medicinal liquids.
15)Under all operating conditions, the maximum temperature achieved in the medication cup chamber above ambient temperature is 5 ℃. l
16)When atomizing, keep the nebulizer cup perpendicular to the horizontal plane.
17)Before disassembly and assembly, please ensure that the nebulizer cup is disconnected from the air source.
18)Do not use for patients who are unconscious or are not breathing spontaneously.
19)Do not use for patients with acute pulmonary edema.
20)Do not use for patients who have completely lost the ability to spontaneously expectorate.
21)Do not use for premature neonate and newborns.
22)Pregnant or breastfeeding women perform inhalation therapy should be favor of physician.
23)Patient who is allergic to aerosolized drugs seek medical attention promptly.
Technical items | Information |
Device type | Pneumatic Jet Nebulizer |
Principle | Venturi effect |
Aerosolization | Continuous during inhalation and exhalation |
Device type | Reusable Device for single patient use |
Gas resource | Compressed air |
Air flow range | 4-8 L/min |
Maximum medication volume | 8 mL±0.8mL |
Minimum medication volume | 2mL |
Aerosol output rate
| 4L/min Cap open: appro. 0.09 ml/min Cap closed: appro. 0.04 ml/min 6L/min Cap open: appro. 0.12 ml/min Cap closed: appro. 0.05 ml/min 8 L/min Cap open: appro. 0.14 ml/min Cap closed: appro. 0.08 ml/min |
MMAD | 4L/min Cap open: appro. 5.1um Cap closed: appro.4.0um 6L/min Cap open: appro. 3.2um Cap closed:appro. 3.1um 8 L/min Cap open: appro. 2.9um Cap closed:appro. 2.7um |
Respirable fraction: | 4L/min Cap open: appro. 49.0% Cap closed:appro. 61.7% 6L/min Cap open: appro. 71.1% Cap closed:appro. 72.0% 8L/min Cap open: appro. 75.5% Cap closed:appro. 76.6% |
Residue volume | ≤1.0 mL |
The NK-101 nebulizer kit includes below accessories:
Model Accessory | NK-101(Mask and Mouthpiece Type) |
Nebulizer Cup | √ |
Air Tube | √ |
Mouthpiece | √ |
Mask (Adult, Child and Infant) | Optional |
Nosepiece | Optional |
Q: Are you trading company or factory?
A: Joytech Healthcare is a factory manufacturing home-care medical devices such as digital thermometers, digital blood pressure monitors, nebulizers, pulse oximeters, etc. We will show you our factory price and factory direct quality products.
Q: Are these nebulizer accessories compatible with all models?
A: Our nebulizer accessories are compatible with all Joytech nebulizers and most standard nebulizer interfaces. However, we recommend checking your model before purchasing. If unsure, please contact our customer service.
Q: How should I clean the nebulizer cup and mask?
A: After each use, clean with warm water and mild detergent. Regular disinfection is recommended. Avoid high-temperature boiling or alcohol-based cleaners to prevent material damage.
Intended Purpose: The nebulizer kit is intended to aerosolize medication for inhalation therapy.
Indications for use: The nebulizer kit is intended to aerosolize medication for inhalation by a patient in the hospital, clinic or home care environment. And the patient include all patients except for premature neonate and newborns.The nebulizer is a single patient use device.
Contraindications:None
Indications
Asthma, Chronic obstructive pulmonary disease (COPD),Cystic fibrosis, Respiratory tract infection, etc disease of respiratory system.
Intended patient: Adult, child and infant.
Warning/cautions
1)The product is strictly prohibited to use after the service life.
2)Keep the nebulizer kit out of reach of unsupervised infants and children. The device may contain small accessories that may post a choking hazard.
3)Children, infants, ally ill person or those without self-awareness shall not be used without adult supervision.
4)For the type, dose and regime of medication please follow follow the doctor's advice.
5)The coma and thick sputum patients should follow the doctor's advice.
6)The solution of the medication cup should not exceed the maximum amount of solution marked by the cup body of the liquid cup, otherwise the nebulization effect will be affected.
7)Use Population: patients with respiratory disease or syndrome, patients with asthma, chronic bronchitis, upper respiratory tract infection, chronic obstructive pulmonary disease, and other lung diseases.
8)If there are wounds on the area where the mask is used, protective measures should be taken in advance.
9)The use of high concentration of liquid medicine for atomization may block the airflow nozzle, leading to No nebulization or low nebulization rate.
10)The Nebulizer is not available for the respiratory anesthesia system and the ventilator system.
11)Can be connected to compressed air supply for nebulization.
12)Compressed air is recommended as a drive in COPD patients and elderly patients with pulmonary insufficiency.
13)The size of the nebulization rate is related to the flow of air, please pay attention to adjust! The recommended compressed air is 4-8 L/min.
14)Do not place or carry nebulizers containing medicinal liquids.
15)Under all operating conditions, the maximum temperature achieved in the medication cup chamber above ambient temperature is 5 ℃. l
16)When atomizing, keep the nebulizer cup perpendicular to the horizontal plane.
17)Before disassembly and assembly, please ensure that the nebulizer cup is disconnected from the air source.
18)Do not use for patients who are unconscious or are not breathing spontaneously.
19)Do not use for patients with acute pulmonary edema.
20)Do not use for patients who have completely lost the ability to spontaneously expectorate.
21)Do not use for premature neonate and newborns.
22)Pregnant or breastfeeding women perform inhalation therapy should be favor of physician.
23)Patient who is allergic to aerosolized drugs seek medical attention promptly.
Technical items | Information |
Device type | Pneumatic Jet Nebulizer |
Principle | Venturi effect |
Aerosolization | Continuous during inhalation and exhalation |
Device type | Reusable Device for single patient use |
Gas resource | Compressed air |
Air flow range | 4-8 L/min |
Maximum medication volume | 8 mL±0.8mL |
Minimum medication volume | 2mL |
Aerosol output rate
| 4L/min Cap open: appro. 0.09 ml/min Cap closed: appro. 0.04 ml/min 6L/min Cap open: appro. 0.12 ml/min Cap closed: appro. 0.05 ml/min 8 L/min Cap open: appro. 0.14 ml/min Cap closed: appro. 0.08 ml/min |
MMAD | 4L/min Cap open: appro. 5.1um Cap closed: appro.4.0um 6L/min Cap open: appro. 3.2um Cap closed:appro. 3.1um 8 L/min Cap open: appro. 2.9um Cap closed:appro. 2.7um |
Respirable fraction: | 4L/min Cap open: appro. 49.0% Cap closed:appro. 61.7% 6L/min Cap open: appro. 71.1% Cap closed:appro. 72.0% 8L/min Cap open: appro. 75.5% Cap closed:appro. 76.6% |
Residue volume | ≤1.0 mL |
The NK-101 nebulizer kit includes below accessories:
Model Accessory | NK-101(Mask and Mouthpiece Type) |
Nebulizer Cup | √ |
Air Tube | √ |
Mouthpiece | √ |
Mask (Adult, Child and Infant) | Optional |
Nosepiece | Optional |
Q: Are you trading company or factory?
A: Joytech Healthcare is a factory manufacturing home-care medical devices such as digital thermometers, digital blood pressure monitors, nebulizers, pulse oximeters, etc. We will show you our factory price and factory direct quality products.
Q: Are these nebulizer accessories compatible with all models?
A: Our nebulizer accessories are compatible with all Joytech nebulizers and most standard nebulizer interfaces. However, we recommend checking your model before purchasing. If unsure, please contact our customer service.
Q: How should I clean the nebulizer cup and mask?
A: After each use, clean with warm water and mild detergent. Regular disinfection is recommended. Avoid high-temperature boiling or alcohol-based cleaners to prevent material damage.