Certificates: | |
---|---|
Measurement Method: | |
Power Source: | |
Nature of Business: | |
Availability: | |
DBP-6675B
Joytech / OEM
The DBP-6675B is more than just an upper-arm blood pressure monitor—it's a comprehensive cardiovascular screening tool. With built-in ECG functionality, this model empowers users to perform quick heart health checks anytime, anywhere. The device seamlessly connects to a mobile app via Bluetooth® 5.0, enabling real-time data sync, intuitive visualizations, and effortless sharing with healthcare providers. Designed for both personal use and professional remote monitoring, the DBP-6675B ensures users have access to advanced health analytics beyond standard blood pressure metrics.
· Measure on inflation
· ECG function
· Quick connection via Bluetooth® 5.0
· Easy Data management and sharing by mobile App
· Blood pressure risk indicator
· Irregular heartbeat detection
· AFib detection
· Backlight optional
· Talking optional
· Talking optional
· Bluetooth optional
· Bradycardia and tachycardia detection
· X-Large display
· 2 × 150 memories with date and time
· Low battery detection
· 3 × “AAA” batteries or Type-C
· Average last 3 results
· Automatic power-off
FAQ
Q1: What makes this model different from standard blood pressure monitors?
The DBP-6675B integrates ECG measurement into a traditional BP monitor, offering a dual diagnostic tool for cardiovascular health.
Q2: Which app does the device connect to, and is it free?
It connects to our free proprietary mobile app via Bluetooth® 5.0. The app is available on both Android and iOS for data tracking, viewing, and export. For OEM/ODM partners, we also offer custom app development services.
Q3: Can I use it without the app?
Absolutely. All core functions work independently of the app. Users can directly read systolic / diastolic pressure and pulse rate on the device’s large display screen. The app is optional but offers added value, such as ECG viewing, history storage, and long-term data analysis.
OUR EXHIBITI
Product Description | ECG Blood Pressure Monitor | |
Model | DBP-6675B | |
Display | LCD Digital Display Size: 118mm×65mm (4.65" x 2.56") | |
Measurement Method | Oscillometric Method | |
Pressurization | Automatic Pressurization | |
BP Measurement Range | Systolic Pressure | 60~260mmHg |
Diastolic Pressure | 40~200mmHg | |
Pulse | 30~180Beats/Minute | |
BP Measurement Accuracy | Pressure Accuracy | ±3mmHg or ±2% above 200 mmHg |
Pulse Accuracy | 30~39Beats/Minute ±5BPM | |
40~180Beats/Minute ±5% | ||
ECG Measurement Method | Single-channel ECG | |
ECG Measurement Range | bandwidth | 0.67~40HZ |
Heart Rate | 30 ~ 199 Beats/Minute | |
Measuring Time | 30 Seconds | |
ECG Measurement Accuracy | Heart Rate | ±5% |
Memory | 2x150 BP Memories in Two Groups with Date and Time 2x20 ECG Memories in Two Groups with Date and Time | |
BP Function | Irregular Heartbeat Detection | |
WHO Classification Indicator | ||
Last 3 Tests Average | ||
ECG Function | Atrial Fibrillation Indicator | |
Normal Sinus Rhythm,Bradycardia,Tachycardia | ||
Other Function | Automatic Power-Off | |
Low Battery Detection | ||
Voice | ||
Backlight | ||
Power Source | 3pcs of AAA batteries / Lithium battery optional | |
Battery Life | Approximately 2 months at 3 tests per day | |
Unit Weight | Approx.426g (16.3 oz.) (including battery) | |
Unit Dimensions | Approx.128 x 130 x 44mm (5.04" x 5.12" x 1.73" )(L x W x H) | |
Optional Cuff Circumference | Fits arm circumference 22cm~36 cm Fits arm circumference 22cm~42 cm Fits arm circumference 32cm~48 cm, select one. | |
Electrode sheet material | Stainless steel | |
Operating Environment | Temperature | 10℃ ~ 40℃ (50℉~104℉) |
Humidity | 15% ~ 93%RH | |
Pressure | Atmospheric Pressure, 800hPa~1060hPa | |
Storage Environment | Temperature: | -25℃~55℃ (-13℉~131℉) |
Humidity | ≤93%RH | |
Bluetooth | Frequency | 2.4GHz(2400-2483.5Mhz) |
Type Of Antenna | Built-in Onboard Antenna | |
Transmission power | About 3dbm | |
Classification: | Internal Powered Equipment, Type BF | |
Ingress Protection Rating | IP21 Indoor Use Only |
Important Instructions Before Use
1. Do not confuse self-monitoring with self-diagnosis. Blood pressure measurements should only be interpreted by a health professional who is familiar with your medical history.
2. Contact your physician if test results regularly indicate abnormal readings.
3. If you are taking medication, consult with your physician to determine the most appropriate time to measure your blood pressure. NEVER change a prescribed medication without first consulting with your physician.
4. Individuals with serious circulation problems may experience discomfort. Consult your physician prior to use.
5. For persons with irregular or unstable circulation resulting from diabetes, liver disease, arteriosclerosis or other medical conditions, there may be variations in blood pressure values measured at the wrist versus at the upper arm. Monitoring the trends in your blood pressure taken at either the arm or the wrist is nevertheless useful and important.
6. People with vasoconstriction, liver disease or diabetes, women with weak pulse
s, pregnant women should consult their doctor before measuring their own blood pressure, different values may be obtained due to their condition.
7. People suffering from arrhythmias such as atrial or ventricular premature beats or atrial fibrillation only use this ECG Blood Pressure Monitor in consultation with your doctor. In certain cases oscillometric measurement method can produce incorrect readings.
8. Too frequent measurements can cause injury to the patient due to blood flow interference.
9. The cuff should not be applied over a wound as this can cause further injury.
10. DO NOT attach the cuff to a limb being used for IV infusions or any other intravascular access, therapy or an arterio-venous (A-V) shunt. The cuff inflation can temporarily block blood flow, potentially causing harm to the patient.
11. The cuff should not be placed on the arm on the side of a mastectomy. In the case of a double mastectomy use the side of the least dominant arm.
12. Pressurization of the cuff can temporarily cause loss of function of simultaneously used monitoring equipment on the same limb.
13. A compressed or kinked connection hose may cause continuous cuff pressure resulting in blood flow interference and potentially harmful injury to the patient.
14. Check that operation of the unit does not result in prolonged impairment of the circulation of the patient.
15. Product is designed for its intended use only. Do not misuse in any way.
16. Product is not intended for infants or individuals who cannot express their intentions.
17. Prolonged over-inflation of the bladder may cause ecchymoma of your arm.
18. Do not disassemble the unit or arm cuff. Do not attempt to repair.
19. Use only the approved arm cuff for this unit. Use of other arm cuffs may result in incorrect measurement results.
20. This product is not intended for users wearing implantable pacemakers
21. The system might produce incorrect readings if stored or used outside the manufacturer's specified temperature and humidity ranges.
22. Do not use the device near strong electrical or electromagnetic fields generated by cell phones or other devices, they may cause incorrect readings and interference or become interference source to the device. Do not use the device during patient transport outside healthcare facility for interference source existing as well.
23. Do not mix new and old batteries simultaneously.
24. Replace batteries when "Low Battery Indicator" appears on screen. Replace both batteries at the same time.
25. Do not mix battery types. Long-life alkaline batteries are recommended.
26. Remove batteries from device when not in operation for more than 3 months.
27. Do not insert the batteries with their polarities incorrectly aligned.
28. Dispose batteries properly; observe local laws and regulations.
29. Do not touch the electrode of this product to other conductors (including grounding).
30. During ECG measurement, if your skin or hands are too dry, please moisten it with a damp towel. Implement measurement.
31. When the electrode surface is dirty, please wipe it with a damp cloth or alcohol cotton, at least once a month.
32. During ECG measurement, please do not use the product in reverse directions with your left and right hands.
33. The performance of automatic ecg sphygmomanometer may be affected by extreme temperature, humidity and altitude.
34. Advising operator that Instruction manual/ Booklet must be consulted.
35.The time required for the device to warm from the minimum storage temperature (-25°C) between use until the device is ready for use at Ambient Temperature 20°C: about 2 hours.
36.The time required for the device to cool from the maximum storage temperature (70°C) between use until the device is ready for use at ambient temperature (20 °C) : about 2 hours.
Establish in 2002, JOYTECH HEALTHCARE CO.,LTD is a fast growing Hi-Tech electronic manufacturer with a primary focus on designing and manufacturing home-care medical instruments in China with more than 20 years' experience.
Our innovative and technological excellence supports production of high quality devices such as digital thermometer and infrared thermometer, blood pressure monitor, breast pump, compressor nebulizer, pulse oximeter and etc.
Where is you factory located? How can I visit there?
Our factory is located in Hangzhou, Zhejiang Province, China, about 1 hour by train from Shanghai. All our clients from home or abroad are warmly welcome!
How many branches does Joytech Healthcare Co., Ltd have?
Joytech Healthcare Co., Ltd has three branches located in China, Cambodia, and America. The headquarters is in Hangzhou, China.
How many employees does Joytech Healthcare Co., Ltd have and what are their roles?
Joytech Healthcare Co., Ltd has more than 2000 employees, including 100 R&D members and 100 QC members, who contribute to the development and quality control of the company's products.