| Ubukhulu beyunithi: | |
|---|---|
| Umthombo wamandla: | |
| Uhlobo Lwebhizinisi: | |
| Ukunikezwa Kwesevisi: | |
| Ukutholakala: | |
I-XM-101
Joytech / OEM
I-XM-101 Bluetooth Fingertip Pulse Oximeter iyidivayisi ehlangene, engasindi, futhi esebenziseka kalula edizayinelwe ukuletha ukuqapha okunembile kwesikhathi sangempela kokugcwala komoyampilo egazini (SpO₂), izinga lokushaya kwenhliziyo (PR), inkomba ye-perfusion (PI), ne-waveform.
Ngokusetshenziswa kwamandla okuphansi kanye nedizayini ephathekayo, ilungele kokubili ukusetshenziswa kwasekhaya kanye nokuphathwa kwezempilo lapho usohambeni.
Ifaka isibonisi esinamaleveli okukhanya alungisekayo (1–5) , idivayisi iqinisekisa ukufundwa okucacile ezimeni ezihlukahlukene zokukhanya.
Isexwayiso esibonakalayo se-voltage ephansi sazisa abasebenzisi lapho amandla ebhethri enganele, kuyilapho umsebenzi wokuvala amandla ngokuzenzakalela usebenza phakathi kwamasekhondi angu-10 ekutholeni 'khipha umunwe', ukonga amandla.
I-XM-101 iphinde ifake ibhiphu nomsebenzi wesikhumbuzi : uma inikwe amandla, isibonisi sizokhanyisa futhi i-buzzer izozwakala njengesexwayiso esengeziwe, esithuthukisa ukuqwashisa komsebenzisi.
Ngoxhumo lwe-Bluetooth , imiphumela ingadluliswa kalula futhi ilandelelwe kumadivayisi ahlakaniphile ahambisanayo, okuhlinzeka ngomuzwa wokuqapha wezempilo oxhumeke kakhulu.
Iqinile, ithembekile, futhi kulula ukuyisebenzisa, i-XM-101 iyisixazululo esiphephile nesisebenzayo semindeni efuna ukuqapha ukugcwala komoyampilo kanye nokushaya kwenhliziyo ngokunethezeka ekhaya.
Beep namathiphu
Ukucisha amandla okuzenzakalelayo
Isisindo esilula futhi kulula ukusithwala
Ukukhanya okulungisekayo
Idizayini ehlakaniphile yokonga amandla, amabhethri 'AAA' angu-2
Isibonisi sombala ombaxambili, ukubuka okungaphenduki okungu-360°
Imodeli |
XM-101/XM-111 |
Uhlobo |
Umunwe we-pulse oximeter |
Indlela Yokukala |
Uhlobo lokudlulisela |
Uhlobo lokubonisa |
Isibonisi esinemibala emibili |
I-SpO2 Display Range |
0%-100% |
Ibanga Lokulinganisa le-SpO2 |
70%-100% |
Ibanga Lokubonisa Isilinganiso Sokushayeka |
0-240bpm |
I-Pulse Rate Measurement Range |
30-240bpm |
Imibandela Yokugijima |
5-40 ℃ |
Usayizi Wokubonisa |
0.96 intshi |
Umswakama |
15%-93%RH |
Ingcindezi |
700hPa-1060hPa |
I-SpO2 |
Yebo |
I-Pulse Rate |
Yebo |
Ukukhanya Okulungisekayo |
Yebo |
Ukucisha amandla okuzenzakalelayo |
Yebo |
Amabhiphu |
Yebo |
Okuqukethwe Oksijini Okuphansi |
Yebo |
I-Bluetooth |
Ongakukhetha |
Umthombo wamandla |
2'AAA'amabhethri |
Khumbuza ngomunwe |
Yebo |
Ukuchithwa kwamandla |
<60mA |
Isikhathi sokubuyekezwa kwedatha |
< 12S |
RED |
Cishe. 660nm Cishe. 3.2mW |
I-IR |
Cishe. 905nm Cishe. 2.4mW |
Iyunithi Dimension |
60.2x35x35.5mm |
Isisindo Seyunithi |
Cishe. awu 54g |
Ukupakisha |
1 pc / Ibhokisi lesipho; 60 ama-pcs / Ibhokisi |
I-Carton Dimensions |
36x22.5x35cm |
Isisindo se-Carton(GW) |
6.7kg |
• 2Iminyaka emi-4 yobungcweti be-OEM ne-ODM.
• Izikhungo ezi-3 zokukhiqiza ezinezinsiza ezizenzakalelayo ezingu-260,000㎡ kanye nezindawo zokugcina impahla ezizenzakalelayo ezingu-2000㎡.
• 30+ imigqa yokukhiqiza kanye 100+ nokuqanjwa okunelungelo lobunikazi.
• ISO 13485, MDSAP, BSCI amasistimu ekhwalithi aqinisekisiwe.
• Ukwenza ngokwezifiso okugcwele kwemikhiqizo yomhlaba wonke, okuhlanganisa ozakwethu be-Fortune 500.

• I-WHX Dubai (ngaphambili eyayaziwa nge-Arab Health), i-Dubai
• I-WHX Miami (ngaphambilini eyayiyi-FIME), e-Miami, e-USA
• I-Hong Kong Electronics Fair, e-Hong Kong
• I-ABC Kids Expo, e-USA
• KIMES, Seoul, Korea
• MEDITEX Bangladesh, Dhaka
• Hospitalar, São Paulo, Brazil
• I-Canton Fair, e-China
• I-MEDICA, Düsseldorf, Germany
Sizibophezele ekuhlanganeni nozakwethu emhlabeni wonke emibukisweni ehamba phambili yamazwe ngamazwe yezokwelapha nezempilo yabathengi.

Q: Umsebenzi we-Bluetooth ukukhulisa kanjani ukuqapha kwemindeni?
A: Ivumela abasebenzisi abaningi ukuthi bavumelanise ukufundwa kwabo kuhlelo lokusebenza lwe-smartphone. Lokhu kuvumela umndeni wonke ukuthi ulandelele i-SpO₂ ngayinye kanye nezinga lokushaya kwenhliziyo kalula endaweni eyodwa.
Q: Ingabe izindlela zokubonisa zisiza kanjani ezimeni ezahlukene?
I: Ukukhanya okungalungiseka kukuvumela ukuthi wenze ngendlela oyifisayo ukubuka kwesikrini ukuze kucace, kungaba segumbini elimnyama ebusuku noma ekukhanyeni kwasemini, ukuqinisekisa ukuthi ukufundwa kuhlala kubonakala kulula.
Q: Yini eyenza le modeli ibe yisinqumo esisebenzayo sokuphatha impilo yasekhaya?
A: Inhlanganisela yayo yokunemba kwebanga lezokwelapha, ukusebenza okulula kwenkinobho eyodwa, kanye nekhono lokungena idatha nge-Bluetooth kuyenza ibe ithuluzi elithembekile nelisebenziseka kalula lokubheka ukuphila kahle kwawo wonke amalungu omndeni.
Ukuze uthole izixazululo ezenziwe ngokwezifiso noma imibuzo yozakwethu, sicela usithinte ku marketing@sejoygroup.com ukuxoxa ngezidingo zakho ezithile.
1. Ngaphambi kokuyisebenzisa, funda ngokucophelela imanuwali.
2. Ungasebenzisi i-pulse oximeter:
-Uma ungezwani nemikhiqizo yenjoloba.
-Uma idivayisi noma umunwe kunomswakama.
-Ngesikhathi MRI noma CT scan.
-Ngenkathi uthatha isilinganiso somfutho wegazi engalweni.
-I-nail polish, ingcolile, i-coating iminwe nezinzipho zamanga ezifakwe iminwe.
-Iminwe enezinguquko ze-anatomical, edemas, izibazi noma ukusha.
-Umunwe omkhulu kakhulu: ububanzi bomunwe bungaphezu kuka-20mm futhi ukujiya kungaphezu kuka-15mm.
-Umunwe omncane kakhulu: ububanzi bomunwe bungaphansi kuka-10mm futhi ukujiya kungaphansi kuka-5mm.
-Izingane ezingaphansi kweminyaka eyi-18.
-Ukukhanya kwemvelo kushintsha kakhulu.
-Iseduze nezingxube zegesi ezivuthayo noma eziqhumayo.
3. Ukusetshenziswa isikhathi eside kungase kubangele ubuhlungu kubantu abanezinkinga zokujikeleza kwegazi. Ungasebenzisi i-pulse oximeter isikhathi esingaphezu kwamahora amabili emunweni owodwa.
4. Izilinganiso zingezemininingwane yakho kuphela - azinakuthatha indawo yokuhlolwa kodokotela. Uma ukufundwa okungalindelekile kwenzeka, opharetha angathatha izilinganiso eziningi futhi abonane nodokotela.
5. Hlola i-pulse oximeter njalo ngaphambi kokuyisebenzisa ukuze uqinisekise ukuthi akukho monakalo obonakalayo futhi namabhethri asashajwe ngokwanele. Esimeni sokungabaza, ungasebenzisi idivayisi futhi uxhumane namasevisi amakhasimende noma umthengisi ogunyaziwe.
6. Ungasebenzisi noma yiziphi izingxenye ezengeziwe ezingatuswanga umenzi.
7. Noma yiziphi izimo musa ukuzivula noma ukulungisa idivayisi uwedwa. Ukwehluleka ukuthobela lokho kuzoholela ekushayweni kwewaranti. Ukuze ulungise, sicela uxhumane namasevisi amakhasimende noma umthengisi ogunyaziwe.
8. Ungabheki ngqo ngaphakathi kwendlu ngesikhathi sokulinganisa. Ukukhanya okubomvu nokukhanya kwe-infrared okungabonakali ku-pulse oximeter kuyingozi emehlweni akho.
9. Lolu cingo aluhloselwe ukusetshenziswa abantu (kuhlanganise nezingane) abanamakhono alinganiselwe angokomzimba, ezinzwa noma engqondo noma abangenalo ulwazi noma ukuntula ulwazi, ngaphandle uma begadwe ngumuntu onomthwalo wemfanelo wokuphepha kwabo noma bethola iziqondiso kulo muntu zokuthi lusetshenziswa kanjani ucingo. Izingane kufanele zigadwe eduze kwedivayisi ukuqinisekisa ukuthi azidlali ngayo.
10. Uma iyunithi igcinwe emazingeni okushisa angaphansi kuka-0℃, yishiye endaweni efudumele cishe amahora amabili ngaphambi kokuyisebenzisa.
11. Uma iyunithi igcinwe emazingeni okushisa angaphezu kwama-40, yishiye endaweni epholile cishe amahora amabili ngaphambi kokuyisebenzisa.
12. Izibonisi zebha ye-pulse azivumeli amandla okushaya kwenhliziyo noma ukuzungeza ukuthi ahlolwe endaweni yokulinganisa. Kunalokho, asetshenziswa ngokukhethekile ukuze abonise ukuhluka kwesignali ebonakalayo yamanje endaweni yokulinganisa futhi akuniki amandla okuhlola ukushaya kwenhliziyo.
13. Ukusebenza kwe-fingertip pulse oximeter kungase kuthinteke ngokusetshenziswa kwe-electrosurgical unit (ESU).
14. Landela izimiso zendawo kanye neziyalezo zokugaywa kabusha mayelana nokulahlwa noma ukugaywa kabusha noma idivayisi nezingxenye zedivayisi, okuhlanganisa namabhethri.
15. Lo mshini uthobelana ne-IEC 60601-1-2 yokuhambisana kwe-electromagnetic kumishini yezokwelapha kagesi namasistimu. Esikhungweni sokunakekelwa kwezempilo noma kwenye indawo, okokusebenza kwawo komsakazo kanye nokuphazamiseka kazibuthe kagesi kungase kuthinte ukusebenza kwe-oximeter.
16. Lokhu okokusebenza akuhloselwe ukusetshenziswa ngesikhathi sokuthutha isiguli ngaphandle kwesikhungo sokunakekelwa kwezempilo.
17. Uma isignali ingazinzile, ukufundwa kungase kungalungile. Sicela ungabhekiseli.
18. Impahla ye-RF yezokuxhumana ephathekayo nehambayo ingaba nomthelela ezintweni zikagesi zezokwelapha.
19. ISEXWAYISO: Ukusetshenziswa kwalesi sixhobo esiseduze noma esipakishwe nezinye izinto zokusebenza kufanele kugwenywe ngoba kungaholela ekusebenzeni ngendlela engafanele. Uma ukusetshenziswa okunjalo kudingekile, lesi sisetshenziswa kanye nezinye izinto zokusebenza kufanele zibhekwe ukuze kuqinisekiswe ukuthi zisebenza ngokujwayelekile.
20. ISEXWAYISO: Impahla yokuxhumana ye-RF EPHATHEKAYO (okuhlanganisa namapheripheral afana nezintambo zezimpondo nezimpondo zangaphandle) kufanele zisetshenziswe kungabikho eduze kuka-30cm (amayintshi angu-12) kunoma iyiphi ingxenye ye-Fingertip Pulse Oximeter, okuhlanganisa izintambo ezishiwo UMenzi. Uma kungenjalo, kungase kubangele ukwehla kokusebenza kwalesi sisetshenziswa.
21. Noma isiphi isigameko esibi kakhulu esenzeke mayelana nocingo kufanele kubikwe kumkhiqizi kanye nesiphathimandla esinekhono seZwe eliyiLungu lapho kusungulwe khona umsebenzisi kanye/noma isiguli.