DBP-6677B
Joytech / OEM
With Bluetooth® 5.0 connectivity, data management and sharing are effortless, DBP-6677B ensures that your personal privacy is fully protected.
It incorporates ±3mmHg high accuracy and a triple measurement function, so that the readings you get are of high accuracy and stability. The 3-color blood pressure indicator clearly displays blood pressure levels—normal, elevated and high, helping users easily interpret their readings.
The large display and optional talking function make it easy to access your results, even for users with visual or auditory limitations. As a multifunctional blood pressure monitor, it not only measures your blood pressure, but also detects cardiovascular risks, facilitating early intervention.
Measurement during inflation
ECG Function
Quick connection via Bluetooth®5.0
Easy data management and sharing
by mobile App
Blood pressure risk indicator
Irregular heartbeat detection
AFib detection optional
Bradycardia and tachycardia detection
Sensitive touch buttons
Talking optional
Backlight optional
2x150 BP memories
2x20 ECG memories
Low battery detection
3×"AAA" batieries or Type-C
Average last 3 results
Extra large display
Automatic power-off
FAQ
Q1: What makes this model different from standard blood pressure monitors?
The DBP-6677B integrates ECG measurement into a traditional BP monitor, offering a dual diagnostic tool for cardiovascular health.
Q2: Which app does the device connect to, and is it free?
It connects to our free proprietary mobile app via Bluetooth® 5.0. The app is available on both Android and iOS for data tracking, viewing, and export. For OEM/ODM partners, we also offer custom app development services.
Q3: Can I use it without the app?
Absolutely. All core functions work independently of the app. Users can directly read systolic / diastolic pressure and pulse rate on the device’s large display screen. The app is optional but offers added value, such as ECG viewing, history storage, and long-term data analysis.
Model | DBP-6677B |
Type | Up-Arm |
BP Measurement Method | Oscillometric Method |
ECG Measurement Method | Single-channel |
Pressure Range | 0 to 299mmHg |
Pulse Range | 30 ~ 180 Beat/ Minute |
Heart Rate Range | 30 ~ 199 Beat/ Minute |
Pressure Accuracy | ±3mmHg |
Pulse Accuracy | ±5% |
Heart Rate Range | ±5% |
ECG Measuring Time | 30 Seconds |
ECG Bandwidth Range | 0.67~40HZ |
Display Size | 10x3.7cm |
Memory Bank | 2x150 BP Memories 2x20 ECG Memories |
Data Time | Month+Day+Hour+Minute |
IHB Detection | YES |
Blood Pressure Risk Indicator | YES |
Average Last 3 Results | YES |
Atrial Fibrillation (AFib) Indicator | YES |
Bradycardia | YES |
Tachycardia | YES |
Included Cuff Size | 22.0-36.0cm ( 8.6''- 14.2'' ) |
Low Battery Detection | YES |
Automatic Power-off | YES |
Power Source | 3 “AAA” or Type C |
Battery Life | About 2 months (test 3 times per day, 30 days per month) |
Backlight | YES |
Talking | YES |
Bluetooth | YES |
Unit Dimensions | 15.0X8.0X4.6cm |
Unit Weight | Approx. 219g |
Packing | 1 pc / Gift box; 24 pcs / Carton |
Carton Size | Approx. 40.5X36.5X43cm |
Carton Weight | Approx. 14kg |
Important Instructions Before Use
1. Do not confuse self-monitoring with self-diagnosis. Blood pressure measurements should only be interpreted by a health professional who is familiar with your medical history.
2. Contact your physician if test results regularly indicate abnormal readings.
3. If you are taking medication, consult with your physician to determine the most appropriate time to measure your blood pressure. NEVER change a prescribed medication without first consulting with your physician.
4. Individuals with serious circulation problems may experience discomfort. Consult your physician prior to use.
5. For persons with irregular or unstable circulation resulting from diabetes, liver disease, arteriosclerosis or other medical conditions, there may be variations in blood pressure values measured at the wrist versus at the upper arm. Monitoring the trends in your blood pressure taken at either the arm or the wrist is nevertheless useful and important.
6. People with vasoconstriction, liver disease or diabetes, women with weak pulse
s, pregnant women should consult their doctor before measuring their own blood pressure, different values may be obtained due to their condition.
7. People suffering from arrhythmias such as atrial or ventricular premature beats or atrial fibrillation only use this ECG Blood Pressure Monitor in consultation with your doctor. In certain cases oscillometric measurement method can produce incorrect readings.
8. Too frequent measurements can cause injury to the patient due to blood flow interference.
9. The cuff should not be applied over a wound as this can cause further injury.
10. DO NOT attach the cuff to a limb being used for IV infusions or any other intravascular access, therapy or an arterio-venous (A-V) shunt. The cuff inflation can temporarily block blood flow, potentially causing harm to the patient.
11. The cuff should not be placed on the arm on the side of a mastectomy. In the case of a double mastectomy use the side of the least dominant arm.
12. Pressurization of the cuff can temporarily cause loss of function of simultaneously used monitoring equipment on the same limb.
13. A compressed or kinked connection hose may cause continuous cuff pressure resulting in blood flow interference and potentially harmful injury to the patient.
14. Check that operation of the unit does not result in prolonged impairment of the circulation of the patient.
15. Product is designed for its intended use only. Do not misuse in any way.
16. Product is not intended for infants or individuals who cannot express their intentions.
17. Prolonged over-inflation of the bladder may cause ecchymoma of your arm.
18. Do not disassemble the unit or arm cuff. Do not attempt to repair.
19. Use only the approved arm cuff for this unit. Use of other arm cuffs may result in incorrect measurement results.
20. This product is not intended for users wearing implantable pacemakers
21. The system might produce incorrect readings if stored or used outside the manufacturer's specified temperature and humidity ranges.
22. Do not use the device near strong electrical or electromagnetic fields generated by cell phones or other devices, they may cause incorrect readings and interference or become interference source to the device. Do not use the device during patient transport outside healthcare facility for interference source existing as well.
23. Do not mix new and old batteries simultaneously.
24. Replace batteries when "Low Battery Indicator" appears on screen. Replace both batteries at the same time.
25. Do not mix battery types. Long-life alkaline batteries are recommended.
26. Remove batteries from device when not in operation for more than 3 months.
27. Do not insert the batteries with their polarities incorrectly aligned.
28. Dispose batteries properly; observe local laws and regulations.
29. Do not touch the electrode of this product to other conductors (including grounding).
30. During ECG measurement, if your skin or hands are too dry, please moisten it with a damp towel. Implement measurement.
31. When the electrode surface is dirty, please wipe it with a damp cloth or alcohol cotton, at least once a month.
32. During ECG measurement, please do not use the product in reverse directions with your left and right hands.
33. The performance of automatic ecg sphygmomanometer may be affected by extreme temperature, humidity and altitude.
34. Advising operator that Instruction manual/ Booklet must be consulted.
35.The time required for the device to warm from the minimum storage temperature (-25°C) between use until the device is ready for use at Ambient Temperature 20°C: about 2 hours.
36.The time required for the device to cool from the maximum storage temperature (70°C) between use until the device is ready for use at ambient temperature (20 °C) : about 2 hours.
Establish in 2002, JOYTECH HEALTHCARE CO.,LTD is a fast growing Hi-Tech electronic manufacturer with a primary focus on designing and manufacturing home-care medical instruments in China with more than 20 years' experience.
Our innovative and technological excellence supports production of high quality devices such as digital thermometer and infrared thermometer, blood pressure monitor, breast pump, compressor nebulizer, pulse oximeter and etc.
Where is you factory located? How can I visit there?
Our factory is located in Hangzhou, Zhejiang Province, China, about 1 hour by train from Shanghai. All our clients from home or abroad are warmly welcome!
How many branches does Joytech Healthcare Co., Ltd have?
Joytech Healthcare Co., Ltd has three branches located in China, Cambodia, and America. The headquarters is in Hangzhou, China.
How many employees does Joytech Healthcare Co., Ltd have and what are their roles?
Joytech Healthcare Co., Ltd has more than 2000 employees, including 100 R&D members and 100 QC members, who contribute to the development and quality control of the company's products.