Availability: | |
---|---|
XM-114
OEM available
The percentage is called blood oxygen saturation, or SpO2. A pulse oximeter also measures and displays the pulse rate at the same time it measures the SpO2 level.
Model | XM-114 | |
Display | LED display | |
SpO2 | Display Range | 0%~100% |
Measurement Range | 70%~100% | |
Accuracy | 70%~100% ±2% 0%~69% no definition | |
Resolution | 1% | |
Pulse Rate | Display Range | 0~240bpm |
Measurement Range Accuracy | 30~240bpm 30~100bpm,±2bpm; 101~240bpm,±2% | |
Resolution | 1bpm | |
Power supply | 2x1.5vAAA batteries | |
Weight | Approx.54g | |
Dimensions | Approx.60mm*32mm*32.9mm | |
Operating Environment | Temperature | 5℃~40℃ |
Humidity | 15%~93%RH | |
Pressure | 700hPa~1060hPa | |
Storage And Transportation Environment | Temperature | -20℃~55℃ |
Humidity | 15%~93%RH | |
Pressure | 700hPa~1060hPa | |
Ingress Protection Rating | IP22 | |
Classification | Internal Powered Equipment Type BF | |
The Date UPDATE period | Less than 12s |
1.Simple to operate and convenient to carry.
2.Small volume, light weight and low power consumption.
3.Displays SpO2, PR, Pulse bar.
4.2 display modes.
5.A low voltage warning will be indicated in visual window when
battery voltage is so low that normal operation of the oximeter
might be influenced.
6.When it shows “---”,the pulse oximeter will power off
automatically in 10 seconds.
7.Beep.
8.When the buzzer and reminder function are turned on, the
numbers on the screen will flash when the reminder occurs, and the
buzzer will beep.
Discover the epitome of accuracy and convenience in health monitoring with our XM-114 Fully Automated LED Fingertip Pulse Oximeter. Designed for home use, this high performance device ensures precise measurements and ease of use for individuals seeking reliable health insights.
Precision Redefined:
Our fingertip pulse oximeter boasts unparalleled accuracy, meeting stringent certification standards for medical devices. Experience confidence in your health data with industry-leading precision in oxygen saturation and pulse rate measurements.
User-Friendly Design:
One-Button Simplicity
Effortlessly navigate through health checks with the XM-114's intuitive one-button operation. No complex settings – just a seamless user experience for individuals of all ages.
Clear LED Display
Stay informed at a glance with the vivid LED display that presents your health metrics in a clear and easy-to-read format. Monitor your oxygen levels and pulse rate with unmatched clarity.
Portable Health Companion:
Compact and lightweight, the XM-114 is your portable health companion. Whether at home or on the go, this fingertip pulse oximeter is designed for maximum convenience. Slip it into your pocket or bag for real-time health monitoring wherever life takes you.
Versatile Health Insights:
Go beyond basic measurements. Our fingertip pulse oximeter provides valuable insights into your overall well-being, allowing you to track trends and make informed decisions about your health.
Conclusion:
Elevate your health monitoring experience with the XM-114 Fully Automated LED Fingertip Pulse Oximeter. Precision, portability, and reliability converge in this state-of-the-art device, empowering you to take control of your well-being. Invest in your health with confidence – choose XM-114 for a brighter and healthier tomorrow.
1. Before use,carefully read the manual.
2. Do not use the pulse oximeter:
-if you are allergic to rubber products.
-if the device or finger is damp.
-during MRI or CT scan.
-while taking a blood pressure measurement on the arm.
-nail polish, dirty, coating fingers and false nails applied fingers.
-fingers with anatomical changes, edemas, scars or burns.
-Too big finger: the width of finger is over than 20mm and the thickness is over
than 15mm.
-Too small finger: the width of finger is less than 10mm and the thickness is less
than 5mm.
-Minors under 18 years old.
-The environmental light changes strongly.
-near flammable or explosive gas mixtures.
3. Extended use may cause pain for people with circulatory disorders. Do not
use the pulse oximeter for longer than two hours on one finger.
4. Measurements are for your information only - they are no substitute for a
medical examination. If an unexpected reading occurs, the operator can
take several more measurements and consult a doctor.
5. Check the pulse oximeter regularly before use to ensure that there is no
visible damage and the batteries are still sufficiently charged. In case of
doubt, do not use the device and contact customer services or authorized
retailer.
6. Do not use any additional parts that are not recommended by the
manufacturer.
7. Any circumstances do not open or repair the device by yourself. Failure to
comply will result in voiding of the warranty. For repairs, please contact
customer services or authorized retailer.
8. Do not look directly inside the housing during the measurement. The red
light and the invisible infrared light in the pulse oximeter are harmful to
your eyes.
9. This device is not intended for use by people (including children) with
restricted physical, sensory or mental skills or a lack of experience or a
lack of knowledge, unless they are supervised by a person who has
responsibility for their safety or they receive instructions from this person
on how to use the device. Children should be supervised around the
device to ensure they do not play with it.
10. If the unit has been stored at temperatures below 0℃, leave it in a warm
place for about two hours before using it.
11. If the unit has been stored at temperatures above 40 , leave it in a cool
place for about two hours before using it.
12. The displays for the pulse bar does not allow the strength of the pulse or
circulation to be evaluated at the measurement site. Rather, they are
exclusively used to display the current visual signal variation at the
measurement site and do not enable diagnostics for the pulse.
13. Operation of the fingertip pulse oximeter may be affected by the use of
an electrosurgical unit (ESU).
14. Follow local ordinances and recycling instructions regarding disposal or
recycling or the device and device components, including batteries.
15.This equipment complies with IEC 60601-1-2 for electromagnetic
compatibility for medical electrical equipment and systems.In healthcare
center or other environment, their radio transmission equipment and
electromagnetic interference may affect the performance of the oximeter.
16. This equipment is not intended for use during patient transport outside
the healthcare facility.
17. When the signal is not stable, the reading may inaccurate. Please do not
reference.
18. Portable and mobile RF communications equipment can affect medical
electrical equipment.
19.WARNING: Use of this equipment adjacent to or stacked with other
equipment should be avoided because it could result in improper
operation. If such use is necessary, this equipment and the other
equipment should be observed to verify that they are operating normally.
20.WARNING: PORTABLE RF communications equipment (includeing
peripherals such as antenna cables and external antennas) should be used
no closer than 30cm (12 inches) to any part of Fingertip Pulse Oximeter,
including cables specified by the MANUFACTURER. Otherwise,
degradation of the performance of this equipment could result.
21. Any serious incident that has occurred in relation to the device should be
reported to the manufacture and the competent authority of the Member
State in which the user and/or patient is established.
The percentage is called blood oxygen saturation, or SpO2. A pulse oximeter also measures and displays the pulse rate at the same time it measures the SpO2 level.
Model | XM-114 | |
Display | LED display | |
SpO2 | Display Range | 0%~100% |
Measurement Range | 70%~100% | |
Accuracy | 70%~100% ±2% 0%~69% no definition | |
Resolution | 1% | |
Pulse Rate | Display Range | 0~240bpm |
Measurement Range Accuracy | 30~240bpm 30~100bpm,±2bpm; 101~240bpm,±2% | |
Resolution | 1bpm | |
Power supply | 2x1.5vAAA batteries | |
Weight | Approx.54g | |
Dimensions | Approx.60mm*32mm*32.9mm | |
Operating Environment | Temperature | 5℃~40℃ |
Humidity | 15%~93%RH | |
Pressure | 700hPa~1060hPa | |
Storage And Transportation Environment | Temperature | -20℃~55℃ |
Humidity | 15%~93%RH | |
Pressure | 700hPa~1060hPa | |
Ingress Protection Rating | IP22 | |
Classification | Internal Powered Equipment Type BF | |
The Date UPDATE period | Less than 12s |
1.Simple to operate and convenient to carry.
2.Small volume, light weight and low power consumption.
3.Displays SpO2, PR, Pulse bar.
4.2 display modes.
5.A low voltage warning will be indicated in visual window when
battery voltage is so low that normal operation of the oximeter
might be influenced.
6.When it shows “---”,the pulse oximeter will power off
automatically in 10 seconds.
7.Beep.
8.When the buzzer and reminder function are turned on, the
numbers on the screen will flash when the reminder occurs, and the
buzzer will beep.
Discover the epitome of accuracy and convenience in health monitoring with our XM-114 Fully Automated LED Fingertip Pulse Oximeter. Designed for home use, this high performance device ensures precise measurements and ease of use for individuals seeking reliable health insights.
Precision Redefined:
Our fingertip pulse oximeter boasts unparalleled accuracy, meeting stringent certification standards for medical devices. Experience confidence in your health data with industry-leading precision in oxygen saturation and pulse rate measurements.
User-Friendly Design:
One-Button Simplicity
Effortlessly navigate through health checks with the XM-114's intuitive one-button operation. No complex settings – just a seamless user experience for individuals of all ages.
Clear LED Display
Stay informed at a glance with the vivid LED display that presents your health metrics in a clear and easy-to-read format. Monitor your oxygen levels and pulse rate with unmatched clarity.
Portable Health Companion:
Compact and lightweight, the XM-114 is your portable health companion. Whether at home or on the go, this fingertip pulse oximeter is designed for maximum convenience. Slip it into your pocket or bag for real-time health monitoring wherever life takes you.
Versatile Health Insights:
Go beyond basic measurements. Our fingertip pulse oximeter provides valuable insights into your overall well-being, allowing you to track trends and make informed decisions about your health.
Conclusion:
Elevate your health monitoring experience with the XM-114 Fully Automated LED Fingertip Pulse Oximeter. Precision, portability, and reliability converge in this state-of-the-art device, empowering you to take control of your well-being. Invest in your health with confidence – choose XM-114 for a brighter and healthier tomorrow.
1. Before use,carefully read the manual.
2. Do not use the pulse oximeter:
-if you are allergic to rubber products.
-if the device or finger is damp.
-during MRI or CT scan.
-while taking a blood pressure measurement on the arm.
-nail polish, dirty, coating fingers and false nails applied fingers.
-fingers with anatomical changes, edemas, scars or burns.
-Too big finger: the width of finger is over than 20mm and the thickness is over
than 15mm.
-Too small finger: the width of finger is less than 10mm and the thickness is less
than 5mm.
-Minors under 18 years old.
-The environmental light changes strongly.
-near flammable or explosive gas mixtures.
3. Extended use may cause pain for people with circulatory disorders. Do not
use the pulse oximeter for longer than two hours on one finger.
4. Measurements are for your information only - they are no substitute for a
medical examination. If an unexpected reading occurs, the operator can
take several more measurements and consult a doctor.
5. Check the pulse oximeter regularly before use to ensure that there is no
visible damage and the batteries are still sufficiently charged. In case of
doubt, do not use the device and contact customer services or authorized
retailer.
6. Do not use any additional parts that are not recommended by the
manufacturer.
7. Any circumstances do not open or repair the device by yourself. Failure to
comply will result in voiding of the warranty. For repairs, please contact
customer services or authorized retailer.
8. Do not look directly inside the housing during the measurement. The red
light and the invisible infrared light in the pulse oximeter are harmful to
your eyes.
9. This device is not intended for use by people (including children) with
restricted physical, sensory or mental skills or a lack of experience or a
lack of knowledge, unless they are supervised by a person who has
responsibility for their safety or they receive instructions from this person
on how to use the device. Children should be supervised around the
device to ensure they do not play with it.
10. If the unit has been stored at temperatures below 0℃, leave it in a warm
place for about two hours before using it.
11. If the unit has been stored at temperatures above 40 , leave it in a cool
place for about two hours before using it.
12. The displays for the pulse bar does not allow the strength of the pulse or
circulation to be evaluated at the measurement site. Rather, they are
exclusively used to display the current visual signal variation at the
measurement site and do not enable diagnostics for the pulse.
13. Operation of the fingertip pulse oximeter may be affected by the use of
an electrosurgical unit (ESU).
14. Follow local ordinances and recycling instructions regarding disposal or
recycling or the device and device components, including batteries.
15.This equipment complies with IEC 60601-1-2 for electromagnetic
compatibility for medical electrical equipment and systems.In healthcare
center or other environment, their radio transmission equipment and
electromagnetic interference may affect the performance of the oximeter.
16. This equipment is not intended for use during patient transport outside
the healthcare facility.
17. When the signal is not stable, the reading may inaccurate. Please do not
reference.
18. Portable and mobile RF communications equipment can affect medical
electrical equipment.
19.WARNING: Use of this equipment adjacent to or stacked with other
equipment should be avoided because it could result in improper
operation. If such use is necessary, this equipment and the other
equipment should be observed to verify that they are operating normally.
20.WARNING: PORTABLE RF communications equipment (includeing
peripherals such as antenna cables and external antennas) should be used
no closer than 30cm (12 inches) to any part of Fingertip Pulse Oximeter,
including cables specified by the MANUFACTURER. Otherwise,
degradation of the performance of this equipment could result.
21. Any serious incident that has occurred in relation to the device should be
reported to the manufacture and the competent authority of the Member
State in which the user and/or patient is established.