Please Choose Your Language
DBP-6175-1
Home » Products » Pulse Oximeter » Fingertip Pulse Oximeter » Fully Automated LED Fingertip Pulse Oximeter for Home Use

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Fully Automated LED Fingertip Pulse Oximeter for Home Use

XM-114 fingertip pulse oximeter is with LED display. A pulse oximeter uses two frequencies of light (red and infrared) to determine the percentage (%)of hemoglobin in the blood that is saturated with oxygen.
Availability:
  • XM-114

  • OEM available

The percentage is called blood oxygen saturation, or SpO2. A pulse oximeter also measures and displays the pulse rate at the same time it measures the SpO2 level.


Specifications


Model


XM-114


Display


LED display


SpO2


Display Range


0%~100%


Measurement Range


70%~100%


Accuracy


70%~100% ±2%

0%~69% no definition


Resolution


1%


Pulse Rate


Display Range


0~240bpm


Measurement Range

Accuracy


30~240bpm

30~100bpm,±2bpm;

101~240bpm,±2%


Resolution


1bpm


Power supply


2x1.5vAAA batteries


Weight


Approx.54g


Dimensions


Approx.60mm*32mm*32.9mm


Operating Environment


Temperature


5℃~40℃


Humidity


15%~93%RH


Pressure


700hPa~1060hPa


Storage And

Transportation

Environment


Temperature


-20℃~55℃


Humidity


15%~93%RH


Pressure


700hPa~1060hPa


Ingress Protection Rating


IP22


Classification


Internal Powered Equipment Type BF


The Date UPDATE period


Less than 12s



Feartures


1.Simple to operate and convenient to carry.

2.Small volume, light weight and low power consumption.

3.Displays SpO2, PR, Pulse bar.

4.2 display modes.

5.A low voltage warning will be indicated in visual window when

battery voltage is so low that normal operation of the oximeter

might be influenced.

6.When it shows “---”,the pulse oximeter will power off

automatically in 10 seconds.

7.Beep.

8.When the buzzer and reminder function are turned on, the

numbers on the screen will flash when the reminder occurs, and the

buzzer will beep.


Discover the epitome of accuracy and convenience in health monitoring with our XM-114 Fully Automated LED Fingertip Pulse Oximeter. Designed for home use, this high performance device ensures precise measurements and ease of use for individuals seeking reliable health insights.


Precision Redefined:

Our fingertip pulse oximeter boasts unparalleled accuracy, meeting stringent certification standards for medical devices. Experience confidence in your health data with industry-leading precision in oxygen saturation and pulse rate measurements.


User-Friendly Design:

One-Button Simplicity

Effortlessly navigate through health checks with the XM-114's intuitive one-button operation. No complex settings – just a seamless user experience for individuals of all ages.


Clear LED Display

Stay informed at a glance with the vivid LED display that presents your health metrics in a clear and easy-to-read format. Monitor your oxygen levels and pulse rate with unmatched clarity.


Portable Health Companion:

Compact and lightweight, the XM-114 is your portable health companion. Whether at home or on the go, this fingertip pulse oximeter is designed for maximum convenience. Slip it into your pocket or bag for real-time health monitoring wherever life takes you.


Versatile Health Insights:

Go beyond basic measurements. Our fingertip pulse oximeter provides valuable insights into your overall well-being, allowing you to track trends and make informed decisions about your health.


Conclusion:

Elevate your health monitoring experience with the XM-114 Fully Automated LED Fingertip Pulse Oximeter. Precision, portability, and reliability converge in this state-of-the-art device, empowering you to take control of your well-being. Invest in your health with confidence – choose XM-114 for a brighter and healthier tomorrow.


Safety Notice


1. Before use,carefully read the manual.

2. Do not use the pulse oximeter:

-if you are allergic to rubber products.

-if the device or finger is damp.

-during MRI or CT scan.

-while taking a blood pressure measurement on the arm.

-nail polish, dirty, coating fingers and false nails applied fingers.

-fingers with anatomical changes, edemas, scars or burns.

-Too big finger: the width of finger is over than 20mm and the thickness is over

than 15mm.

-Too small finger: the width of finger is less than 10mm and the thickness is less

than 5mm.

-Minors under 18 years old.

-The environmental light changes strongly.

-near flammable or explosive gas mixtures.

3. Extended use may cause pain for people with circulatory disorders. Do not

use the pulse oximeter for longer than two hours on one finger.

4. Measurements are for your information only - they are no substitute for a

medical examination. If an unexpected reading occurs, the operator can

take several more measurements and consult a doctor.

5. Check the pulse oximeter regularly before use to ensure that there is no

visible damage and the batteries are still sufficiently charged. In case of

doubt, do not use the device and contact customer services or authorized

retailer.

6. Do not use any additional parts that are not recommended by the

manufacturer.

7. Any circumstances do not open or repair the device by yourself. Failure to

comply will result in voiding of the warranty. For repairs, please contact

customer services or authorized retailer.

8. Do not look directly inside the housing during the measurement. The red

light and the invisible infrared light in the pulse oximeter are harmful to

your eyes.

9. This device is not intended for use by people (including children) with

restricted physical, sensory or mental skills or a lack of experience or a

lack of knowledge, unless they are supervised by a person who has

responsibility for their safety or they receive instructions from this person

on how to use the device. Children should be supervised around the

device to ensure they do not play with it.

10. If the unit has been stored at temperatures below 0℃, leave it in a warm

place for about two hours before using it.

11. If the unit has been stored at temperatures above 40 , leave it in a cool

place for about two hours before using it.

12. The displays for the pulse bar does not allow the strength of the pulse or

circulation to be evaluated at the measurement site. Rather, they are

exclusively used to display the current visual signal variation at the

measurement site and do not enable diagnostics for the pulse.

13. Operation of the fingertip pulse oximeter may be affected by the use of

an electrosurgical unit (ESU).

14. Follow local ordinances and recycling instructions regarding disposal or

recycling or the device and device components, including batteries.

15.This equipment complies with IEC 60601-1-2 for electromagnetic

compatibility for medical electrical equipment and systems.In healthcare

center or other environment, their radio transmission equipment and

electromagnetic interference may affect the performance of the oximeter.

16. This equipment is not intended for use during patient transport outside

the healthcare facility.

17. When the signal is not stable, the reading may inaccurate. Please do not

reference.

18. Portable and mobile RF communications equipment can affect medical

electrical equipment.

19.WARNING: Use of this equipment adjacent to or stacked with other

equipment should be avoided because it could result in improper

operation. If such use is necessary, this equipment and the other

equipment should be observed to verify that they are operating normally.

20.WARNING: PORTABLE RF communications equipment (includeing

peripherals such as antenna cables and external antennas) should be used

no closer than 30cm (12 inches) to any part of Fingertip Pulse Oximeter,

including cables specified by the MANUFACTURER. Otherwise,

degradation of the performance of this equipment could result.

21. Any serious incident that has occurred in relation to the device should be

reported to the manufacture and the competent authority of the Member

State in which the user and/or patient is established.


Previous: 
Next: 
Contact us for a healthier life

Related Products

​LD-2010 electronic breast pump is designed for mom breasfeeding at night with LED lamp. 2-Phase design, easy for stimulation and expression. Single breast pump is helpful for breastfeeding and sucking at the same time.
0
0
XM-114 fingertip pulse oximeter is with LED display. A pulse oximeter uses two frequencies of light (red and infrared) to determine the percentage (%)of hemoglobin in the blood that is saturated with oxygen.
0
0
  • NB-1104 is a compressor nebulizer with stable and high quality motor and safe materials of mask and nozzles.
  • Applicable for children.
  • Factory direct with OEM services.
0
0
DMT-455 pacifier type thermometer is practical for home use when baby is sick and will refuse oral temperature measurement or measure temperature underarm.
Model no.: DMT-455
Measurement range: 32.0 °C to 42.9 °C
Measurement accuracy: ± 0.1 °C between 35.5 °C and 42.0 °C
Battery: 1.5 V battery, size LR41, SR41 or UCC 392
Display: LCD display, size 16.2×7.0mm
0
0
 NO.365, Wuzhou Road, Zhejiang Province, Hangzhou, 311100,China

 No.502, Shunda Road. Zhejiang Province, Hangzhou, 311100 China
 

QUICK LINKS

PRODUCTS

WHATSAPP US

Europe Market: Mike Tao 
+86-15058100500
Asia & Africa Market: Eric Yu 
+86-15958158875
North America Market: Rebecca Pu 
+86-15968179947
South America & Australia Market: Freddy Fan 
+86-18758131106
 
Copyright © 2023 Joytech Healthcare. All Rights Reserved.   Sitemap | Technology by leadong.com