Ukutholakala: | |
---|---|
Xm-112
Isingeniso:
Phakamisa umuzwa wakho wokuqapha impilo nge-XM-112 ukunemba okuphezulu komunwe ophezulu we-pulse oximeter. Yakhelwe ukunemba nokulula ukusetshenziswa, le divayisi yokusika-onqenqemeni iqinisekisa izilinganiso ezithembekile nezinembile zokuhlola okuphelele kwezempilo.
Izilinganiso ezinembile zokuthula kwakho kwengqondo: I-Pulsertip yethu i-pulse oximeter isebenzisa ubuchwepheshe bezinzwa ezithuthukile, okuqinisekisa ukunemba okuphezulu ku-Oxygen Sactation (SPO2) kanye nezilinganiso zezilinganiso zokushaya kwenhliziyo. Qiniseka, ukufundwa ngakunye kuyisibonakaliso sangempela sesimo sakho sempilo.
Ukucaciswa okuqinisekisiwe:
Kuqinisekiswe amazinga embonini, i-XM-112 ihlangana namabhentshi aphezulu kakhulu ngokunemba. Thembela ekuthembekeni kwe-pulse oximeter yethu ngemiphumela engaguquki futhi ethembekile, ukukunikeza amandla okwenza izinqumo ezinolwazi ngenhlala-kahle yakho.
Idizayini evumelana nomsebenzisi:
Izwa lula kutholakale kalula nge-XM-112. Idizayini enobungane yomsebenzisi ifaka ukusebenza kwenkinobho eyodwa yokulula, okuvumela ukukalwa okusheshayo nokungajabulisi. Isibonisi se-LCD esicacile siqinisekisa ukufundeka okungasebenzi kunoma iyiphi imvelo.
I-Portable Health Companion:
I-compact futhi engasindi, i-XM-112 ingumngane wakho wezempilo ophathekayo. Yehla ephaketheni lakho noma esikhwameni sakho, bese ubheka impilo yakho usohambeni. Noma ngabe uhamba, ukuzivocavoca, noma ekhaya, thatha inhlala-kahle yakho ngale divayisi elula.
Ukuhleleka Okuhlekisayo:
Ngaphandle kwe-pulse oximetry, i-XM-112 inikeza izici ezingeziwe zokuthuthukisa umuzwa wakho wokuqapha impilo. [Faka noma yiziphi izici ezingeziwe Umkhiqizo wakho ongaba nazo, ezinjenge-plethysmograph grows noma amazinga wokukhanya okuguqukayo.
Yakhelwe isikhathi eside:
Yakhelwe ukuqina engqondweni, i-XM-112 yakhelwe ukubekezelela ukusetshenziswa kwansuku zonke. Tshala imali kwi-oximeter ye-pulse ebeka isivivinyo sesikhathi, uqinisekise ukunakekelwa kwempilo okuqhubekayo nokuthembekile noma nini lapho uyidinga.
Isiphetho:
Faka i-XM-112 ukunemba okuphezulu komunwe ophakeme pulse oximeter enkambisweni yakho yansuku zonke bese ubeka phambili impilo yakho ngokuzethemba. Thembela ngokunemba, ukuthembeka, kanye lula kwedivaysi yethu yokusika-onqenqemeni ukuze uthole imininingwane efanele yezempilo kutholakale kalula. Oda eyakho manje bese uqala uhambo oluya enhlalakahleni efanele.
Isifanekiso | Xm-112 | |
Bonisa | I-LCD Display | |
Spo2 | Ububanzi bokubonisa | 0% ~ 100% |
Uhla lokulinganisa | I-70% ~ 100% | |
Ukuqonda nqo | I-70% ~ 100% ± 2% 0% ~ 69% akukho ncazelo | |
Isixazululo | 1% | |
I-Parse Rate | Ububanzi bokubonisa | 0 ~ 240bpm |
Uhla lokulinganisa | 30 ~ 240bpm | |
Ukuqonda nqo | 30 ~ 100bpm, ± 2bpm; I-101 ~ 240bpm, ± 2% | |
Isixazululo | I-1BPM | |
Ukunikezwa kwamandla kagesi | 2x1.5vaaa amabhethri | |
Isisindo | Approx.54g | |
Ubukhulu | Approx.60mm * 32mm * 32.9mm | |
Indawo yokusebenza | Izinga lokushisa nokubanda | 5 ℃ ~ 40 ℃ |
Ukuswakama | 15% ~ 93% RH | |
Ukucindezela | 700hpa ~ 1060hpa | |
Isitoreji Futhi Ukuthutha Indawo ezungezile | Izinga lokushisa nokubanda | -20 ℃ ~ 55 ℃ |
Ukuswakama | 15% ~ 93% RH | |
Ukucindezela | 700hpa ~ 1060hpa | |
Isilinganiso sokuvikelwa kwe-Ingress | IP22 | |
Ukuhlela ngohlobo oluthile | I-Enternal Powered Opment hlobo bf | |
Isikhathi sokuvuselela idatha | Ngaphansi kwama-12s |
1.Simple ukuze usebenze futhi elula ukuthwala.
Ivolumu ye-2.Small, isisindo esikhanyayo kanye nokusetshenziswa kwamandla okuphansi.
3.Displays SPO2, PR, Pulse Bar.
4.2 Izindlela zokubonisa.
Isixwayiso esiphansi seVoltage sizokhonjiswa ewindini elibonakalayo lapho
I-Battery Voltage iphansi kangangokuba ukusebenza okujwayelekile kwe-oximeter
kungathonywa.
6.Ukubonisa '---- ', i-pulse oximeter izocima
ngokuzenzakalelayo ngemizuzwana eyi-10.
7.Beep.
8. Lapho umsebenzi we-buzzer kanye nesikhumbuzo uvuliwe,
Izinombolo esikrinini zizokhanya lapho isikhumbuzi senzeka, futhi
I-Buzzer izokhala.
1. Ngaphambi kokusebenzisa, funda ngokucophelela le ncwadi.
2. Ungasebenzisi i-pulse oximeter:
-Uma ungezwani nemikhiqizo yenjoloba.
-Uma idivaysi noma umunwe kungokwenyama.
-I-Scan ye-MRI noma i-CT.
-Ukuthatha ukulinganiswa kwengcindezi yegazi engalweni.
-Izipilizo, ezingcolile, iminwe neminwe neminwe yamanga kusetshenziswe iminwe.
-Finger ngezinguquko ze-anatomical, ama-edemas, izibazi noma ukushiswa.
Umunwe omkhulu we-toonto: Ububanzi bomunwe bungaphezu kwama-20mm futhi ubukhulu buphelile
kune-15mm.
Umunwe omncane -Too: Ububanzi bomunwe bungaphansi kwe-10mm futhi ubukhulu buncane
kune-5mm.
-Imigodi engaphansi kweminyaka eyi-18.
-Ukukhanya kwezemvelo kushintsha ngamandla.
-Izingxube zegesi ezivuthayo noma eziqhumayo.
3. Ukusetshenziswa okunwetshiwe kungadala izinhlungu zabantu abanenkinga yokujikeleza. Ungenzi
Sebenzisa i-pulse oximeter isikhathi esingaphezu kwamahora amabili ngomunwe owodwa.
I-4. Izilinganiso zolwazi lwakho kuphela - azikho esikhundleni se
ukuhlolwa kwezokwelashwa. Uma kwenzeka ukufundwa okungalindelekile, opharetha angakwazi
Thatha ezinye izilinganiso eziningi bese uthintana nodokotela.
5. Bheka i-pulse oximeter njalo ngaphambi kokusebenzisa ukuqinisekisa ukuthi akukho
Umonakalo obonakalayo namabhethri asakhokhiswa ngokwanele. Uma kwenzeka
ukungabaza, ungasebenzisi idivaysi kanye nezinsizakalo zamakhasimende noma ezigunyaziwe
Umthengisi.
6. Ungasebenzisi ezinye izingxenye ezengeziwe ezinganconywa yi
Umkhiqizi.
7. Noma yiziphi izimo azivuli noma zonakalise idivaysi yedwa. Ukwehluleka
Ukuthobela kuzoholela ekunikezelweni kwewaranti. Ukulungiswa, sicela uthinte
Izinsizakalo zamakhasimende noma umthengisi ogunyaziwe.
8. Ungabheki ngqo ngaphakathi kwezindlu ngesikhathi sokulinganisa. Okubomvu
ukukhanya nokukhanya okungabonakali kwe-infrared ku-pulse oximeter kuyingozi kuye
Amehlo akho.
9. Le divayisi ayihloselwe ukusetshenziswa ngabantu (kufaka phakathi izingane) nge
amakhono avinjelwe ngokomzimba, okuzwakalayo noma engqondweni noma ukuntuleka kwesipiliyoni noma a
Ukuntuleka kolwazi, ngaphandle kokuthi kugadwe umuntu onawo
isibopho ngokuphepha kwabo noma bathola imiyalo evela kulo muntu
Ukusebenzisa kanjani idivaysi. Izingane kufanele zigadwe azungeze
Idivaysi yokuqinisekisa ukuthi ayidlali nayo.
10. Uma iyunithi igcinwe emazingeni okushisa angezansi 0 ℃, shiya kufudumele
beka cishe amahora amabili ngaphambi kokuyisebenzisa.
11. Uma iyunithi igcinwe emazingeni okushisa angenhla kwe-40 ℃, shiya kupholile
beka cishe amahora amabili ngaphambi kokuyisebenzisa.
12. Imibukiso yebha ye-pulse ayivumeli amandla okushaya noma
ukujikeleza okumele kuhlolwe endaweni yokulinganisa. Kunalokho, bakhona
kusetshenziswe kuphela ukubonisa ukuhlukahluka kwesiginali yamanje ku
Isayithi lokulinganisa futhi ungavumeli ukuxilongwa kokushaya.
13. Ukusebenza kwe-pulse pulse oximeter kungathintwa ukusetshenziswa kwe
iyunithi ye-electrosurgical (eSU).
14. Landela izimiso zendawo nemiyalo yokuphinda usebenzise kabusha maqondana nokulahlwa noma
Ukuphinda usebenzise kabusha noma idivaysi nezakhi zedivayisi, kufaka phakathi amabhethri.
I-15.Lomishini ihambisana ne-IEC 60601-1-2: 2014 nge-electromagnetic
Ukuhambisana kwemishini kagesi yezokwelapha nezinhlelo.in ezempilo
isikhungo noma enye imvelo, imishini yokuhambisa umsakazo kanye
Ukuphazanyiswa kwe-electromagnetic kungathinta ukusebenza kwe-oximeter.
16. Le mishini ayihloselwe ukusetshenziswa ngesikhathi sokuhamba ngesiguli ngaphandle
Isikhungo Sokunakekelwa Kwezempilo.
17. Lapho isinali lingazinzile, ukufundwa kungakulungile. Ngicela ungabenzi
Inkomba.
18. Imishini yokuxhumana ephathekayo ne-Mobile RF ingathinta ezokwelapha
imishini kagesi.
19.Warning: Ukusetshenziswa kwale mishini eduze noma okuhlanganiswe nezinye
imishini kufanele igwenywe ngoba kungaholela ekungatheni
ukusebenza. Uma ukusetshenziswa okunjalo kuyadingeka, le mishini nokunye
Izinsiza kufanele zibhekwe ukuqinisekisa ukuthi zisebenza ngokujwayelekile.
I-20.Warning: Imishini yokuxhumana ephathekayo ye-RF (ifaka phakathi
izimvume ezinjengezintambo ze-antenna kanye nezimpondo zangaphandle) kufanele zisetshenziswe
akukho eduze kuka-30cm (amasentimitha ayi-12) kunoma iyiphi ingxenye ye-pulse pulse oximeter,
kufaka phakathi izintambo ezichazwe ngumenzi. Ngaphandle kwalokho,
Ukuwohloka kokusebenza kwale mishini kungahle kube nomphumela.
21. Noma yisiphi isehlakalo esibi esenzekile maqondana nedivayisi kufanele
kubikwe ekwenziweni kanye negunya elifanele lelungu
Yisho lapho umsebenzisi kanye / noma isiguli sisungulwa khona.
Isingeniso:
Phakamisa umuzwa wakho wokuqapha impilo nge-XM-112 ukunemba okuphezulu komunwe ophezulu we-pulse oximeter. Yakhelwe ukunemba nokulula ukusetshenziswa, le divayisi yokusika-onqenqemeni iqinisekisa izilinganiso ezithembekile nezinembile zokuhlola okuphelele kwezempilo.
Izilinganiso ezinembile zokuthula kwakho kwengqondo: I-Pulsertip yethu i-pulse oximeter isebenzisa ubuchwepheshe bezinzwa ezithuthukile, okuqinisekisa ukunemba okuphezulu ku-Oxygen Sactation (SPO2) kanye nezilinganiso zezilinganiso zokushaya kwenhliziyo. Qiniseka, ukufundwa ngakunye kuyisibonakaliso sangempela sesimo sakho sempilo.
Ukucaciswa okuqinisekisiwe:
Kuqinisekiswe amazinga embonini, i-XM-112 ihlangana namabhentshi aphezulu kakhulu ngokunemba. Thembela ekuthembekeni kwe-pulse oximeter yethu ngemiphumela engaguquki futhi ethembekile, ukukunikeza amandla okwenza izinqumo ezinolwazi ngenhlala-kahle yakho.
Idizayini evumelana nomsebenzisi:
Izwa lula kutholakale kalula nge-XM-112. Idizayini enobungane yomsebenzisi ifaka ukusebenza kwenkinobho eyodwa yokulula, okuvumela ukukalwa okusheshayo nokungajabulisi. Isibonisi se-LCD esicacile siqinisekisa ukufundeka okungasebenzi kunoma iyiphi imvelo.
I-Portable Health Companion:
I-compact futhi engasindi, i-XM-112 ingumngane wakho wezempilo ophathekayo. Yehla ephaketheni lakho noma esikhwameni sakho, bese ubheka impilo yakho usohambeni. Noma ngabe uhamba, ukuzivocavoca, noma ekhaya, thatha inhlala-kahle yakho ngale divayisi elula.
Ukuhleleka Okuhlekisayo:
Ngaphandle kwe-pulse oximetry, i-XM-112 inikeza izici ezingeziwe zokuthuthukisa umuzwa wakho wokuqapha impilo. [Faka noma yiziphi izici ezingeziwe Umkhiqizo wakho ongaba nazo, ezinjenge-plethysmograph grows noma amazinga wokukhanya okuguqukayo.
Yakhelwe isikhathi eside:
Yakhelwe ukuqina engqondweni, i-XM-112 yakhelwe ukubekezelela ukusetshenziswa kwansuku zonke. Tshala imali kwi-oximeter ye-pulse ebeka isivivinyo sesikhathi, uqinisekise ukunakekelwa kwempilo okuqhubekayo nokuthembekile noma nini lapho uyidinga.
Isiphetho:
Faka i-XM-112 ukunemba okuphezulu komunwe ophakeme pulse oximeter enkambisweni yakho yansuku zonke bese ubeka phambili impilo yakho ngokuzethemba. Thembela ngokunemba, ukuthembeka, kanye lula kwedivaysi yethu yokusika-onqenqemeni ukuze uthole imininingwane efanele yezempilo kutholakale kalula. Oda eyakho manje bese uqala uhambo oluya enhlalakahleni efanele.
Isifanekiso | Xm-112 | |
Bonisa | I-LCD Display | |
Spo2 | Ububanzi bokubonisa | 0% ~ 100% |
Uhla lokulinganisa | I-70% ~ 100% | |
Ukuqonda nqo | I-70% ~ 100% ± 2% 0% ~ 69% akukho ncazelo | |
Isixazululo | 1% | |
I-Parse Rate | Ububanzi bokubonisa | 0 ~ 240bpm |
Uhla lokulinganisa | 30 ~ 240bpm | |
Ukuqonda nqo | 30 ~ 100bpm, ± 2bpm; I-101 ~ 240bpm, ± 2% | |
Isixazululo | I-1BPM | |
Ukunikezwa kwamandla kagesi | 2x1.5vaaa amabhethri | |
Isisindo | Approx.54g | |
Ubukhulu | Approx.60mm * 32mm * 32.9mm | |
Indawo yokusebenza | Izinga lokushisa nokubanda | 5 ℃ ~ 40 ℃ |
Ukuswakama | 15% ~ 93% RH | |
Ukucindezela | 700hpa ~ 1060hpa | |
Isitoreji Futhi Ukuthutha Indawo ezungezile | Izinga lokushisa nokubanda | -20 ℃ ~ 55 ℃ |
Ukuswakama | 15% ~ 93% RH | |
Ukucindezela | 700hpa ~ 1060hpa | |
Isilinganiso sokuvikelwa kwe-Ingress | IP22 | |
Ukuhlela ngohlobo oluthile | I-Enternal Powered Opment hlobo bf | |
Isikhathi sokuvuselela idatha | Ngaphansi kwama-12s |
1.Simple ukuze usebenze futhi elula ukuthwala.
Ivolumu ye-2.Small, isisindo esikhanyayo kanye nokusetshenziswa kwamandla okuphansi.
3.Displays SPO2, PR, Pulse Bar.
4.2 Izindlela zokubonisa.
Isixwayiso esiphansi seVoltage sizokhonjiswa ewindini elibonakalayo lapho
I-Battery Voltage iphansi kangangokuba ukusebenza okujwayelekile kwe-oximeter
kungathonywa.
6.Ukubonisa '---- ', i-pulse oximeter izocima
ngokuzenzakalelayo ngemizuzwana eyi-10.
7.Beep.
8. Lapho umsebenzi we-buzzer kanye nesikhumbuzo uvuliwe,
Izinombolo esikrinini zizokhanya lapho isikhumbuzi senzeka, futhi
I-Buzzer izokhala.
1. Ngaphambi kokusebenzisa, funda ngokucophelela le ncwadi.
2. Ungasebenzisi i-pulse oximeter:
-Uma ungezwani nemikhiqizo yenjoloba.
-Uma idivaysi noma umunwe kungokwenyama.
-I-Scan ye-MRI noma i-CT.
-Ukuthatha ukulinganiswa kwengcindezi yegazi engalweni.
-Izipilizo, ezingcolile, iminwe neminwe neminwe yamanga kusetshenziswe iminwe.
-Finger ngezinguquko ze-anatomical, ama-edemas, izibazi noma ukushiswa.
Umunwe omkhulu we-toonto: Ububanzi bomunwe bungaphezu kwama-20mm futhi ubukhulu buphelile
kune-15mm.
Umunwe omncane -Too: Ububanzi bomunwe bungaphansi kwe-10mm futhi ubukhulu buncane
kune-5mm.
-Imigodi engaphansi kweminyaka eyi-18.
-Ukukhanya kwezemvelo kushintsha ngamandla.
-Izingxube zegesi ezivuthayo noma eziqhumayo.
3. Ukusetshenziswa okunwetshiwe kungadala izinhlungu zabantu abanenkinga yokujikeleza. Ungenzi
Sebenzisa i-pulse oximeter isikhathi esingaphezu kwamahora amabili ngomunwe owodwa.
I-4. Izilinganiso zolwazi lwakho kuphela - azikho esikhundleni se
ukuhlolwa kwezokwelashwa. Uma kwenzeka ukufundwa okungalindelekile, opharetha angakwazi
Thatha ezinye izilinganiso eziningi bese uthintana nodokotela.
5. Bheka i-pulse oximeter njalo ngaphambi kokusebenzisa ukuqinisekisa ukuthi akukho
Umonakalo obonakalayo namabhethri asakhokhiswa ngokwanele. Uma kwenzeka
ukungabaza, ungasebenzisi idivaysi kanye nezinsizakalo zamakhasimende noma ezigunyaziwe
Umthengisi.
6. Ungasebenzisi ezinye izingxenye ezengeziwe ezinganconywa yi
Umkhiqizi.
7. Noma yiziphi izimo azivuli noma zonakalise idivaysi yedwa. Ukwehluleka
Ukuthobela kuzoholela ekunikezelweni kwewaranti. Ukulungiswa, sicela uthinte
Izinsizakalo zamakhasimende noma umthengisi ogunyaziwe.
8. Ungabheki ngqo ngaphakathi kwezindlu ngesikhathi sokulinganisa. Okubomvu
ukukhanya nokukhanya okungabonakali kwe-infrared ku-pulse oximeter kuyingozi kuye
Amehlo akho.
9. Le divayisi ayihloselwe ukusetshenziswa ngabantu (kufaka phakathi izingane) nge
amakhono avinjelwe ngokomzimba, okuzwakalayo noma engqondweni noma ukuntuleka kwesipiliyoni noma a
Ukuntuleka kolwazi, ngaphandle kokuthi kugadwe umuntu onawo
isibopho ngokuphepha kwabo noma bathola imiyalo evela kulo muntu
Ukusebenzisa kanjani idivaysi. Izingane kufanele zigadwe azungeze
Idivaysi yokuqinisekisa ukuthi ayidlali nayo.
10. Uma iyunithi igcinwe emazingeni okushisa angezansi 0 ℃, shiya kufudumele
beka cishe amahora amabili ngaphambi kokuyisebenzisa.
11. Uma iyunithi igcinwe emazingeni okushisa angenhla kwe-40 ℃, shiya kupholile
beka cishe amahora amabili ngaphambi kokuyisebenzisa.
12. Imibukiso yebha ye-pulse ayivumeli amandla okushaya noma
ukujikeleza okumele kuhlolwe endaweni yokulinganisa. Kunalokho, bakhona
kusetshenziswe kuphela ukubonisa ukuhlukahluka kwesiginali yamanje ku
Isayithi lokulinganisa futhi ungavumeli ukuxilongwa kokushaya.
13. Ukusebenza kwe-pulse pulse oximeter kungathintwa ukusetshenziswa kwe
iyunithi ye-electrosurgical (eSU).
14. Landela izimiso zendawo nemiyalo yokuphinda usebenzise kabusha maqondana nokulahlwa noma
Ukuphinda usebenzise kabusha noma idivaysi nezakhi zedivayisi, kufaka phakathi amabhethri.
I-15.Lomishini ihambisana ne-IEC 60601-1-2: 2014 nge-electromagnetic
Ukuhambisana kwemishini kagesi yezokwelapha nezinhlelo.in ezempilo
isikhungo noma enye imvelo, imishini yokuhambisa umsakazo kanye
Ukuphazanyiswa kwe-electromagnetic kungathinta ukusebenza kwe-oximeter.
16. Le mishini ayihloselwe ukusetshenziswa ngesikhathi sokuhamba ngesiguli ngaphandle
Isikhungo Sokunakekelwa Kwezempilo.
17. Lapho isinali lingazinzile, ukufundwa kungakulungile. Ngicela ungabenzi
Inkomba.
18. Imishini yokuxhumana ephathekayo ne-Mobile RF ingathinta ezokwelapha
imishini kagesi.
19.Warning: Ukusetshenziswa kwale mishini eduze noma okuhlanganiswe nezinye
imishini kufanele igwenywe ngoba kungaholela ekungatheni
ukusebenza. Uma ukusetshenziswa okunjalo kuyadingeka, le mishini nokunye
Izinsiza kufanele zibhekwe ukuqinisekisa ukuthi zisebenza ngokujwayelekile.
I-20.Warning: Imishini yokuxhumana ephathekayo ye-RF (ifaka phakathi
izimvume ezinjengezintambo ze-antenna kanye nezimpondo zangaphandle) kufanele zisetshenziswe
akukho eduze kuka-30cm (amasentimitha ayi-12) kunoma iyiphi ingxenye ye-pulse pulse oximeter,
kufaka phakathi izintambo ezichazwe ngumenzi. Ngaphandle kwalokho,
Ukuwohloka kokusebenza kwale mishini kungahle kube nomphumela.
21. Noma yisiphi isehlakalo esibi esenzekile maqondana nedivayisi kufanele
kubikwe ekwenziweni kanye negunya elifanele lelungu
Yisho lapho umsebenzisi kanye / noma isiguli sisungulwa khona.