| Unit Dimension: | |
|---|---|
| Power Source: | |
| Nature of Business: | |
| Service Offering: | |
| Availability: | |
XM-112
Joytech / OEM
Elevate your health monitoring experience with the XM-112 High Accuracy Fingertip Pulse Oximeter. Designed for precision and ease of use, this cutting-edge device ensures reliable and accurate measurements for a comprehensive health assessment.
1. Accurate Measurements:
Our fingertip pulse oximeter employs advanced sensor technology, guaranteeing high accuracy in oxygen saturation (SpO2) and pulse rate measurements. Rest assured, each reading is a true reflection of your health status.
2. Certified Precision:
Certified by industry standards, the XM-112 meets the highest benchmarks for accuracy. Trust in the reliability of our pulse oximeter for consistent and dependable results, empowering you to make informed decisions about your well-being.
3. User-Friendly Design:
Experience convenience at your fingertips with the XM-112. The user-friendly design includes a single-button operation for simplicity, allowing for quick and hassle-free measurements. The clear LCD display ensures effortless readability in any environment.
4. Portable Health Companion:
Compact and lightweight, the XM-112 is your portable health companion. Slip it into your pocket or bag, and monitor your health on the go. Whether you're traveling, exercising, or at home, take control of your well-being with this convenient device.
5. Multifunctional Excellence:
Beyond pulse oximetry, the XM-112 offers additional features to enhance your health monitoring experience. [Include any additional features your product may have, such as a plethysmograph waveform display or adjustable brightness levels.
6. Built for Longevity:
Crafted with durability in mind, the XM-112 is built to withstand daily use. Invest in a pulse oximeter that stands the test of time, ensuring continuous and reliable health monitoring whenever you need it.
Incorporate the XM-112 High Accuracy Fingertip Pulse Oximeter into your daily routine and prioritize your health with confidence. Trust in the precision, reliability, and convenience of our cutting-edge device for accurate health insights at your fingertips. Order yours now and embark on a journey towards optimal well-being.
Beep and tips
Automatic power-off
Light weight and easy to carry
Large LCD display, 2 display modes
Intelligent power saving design, 2 "AAA" batteries
Model | XM-112 |
Type | Fingertip pulse oximeter |
Measurement Method | Transmission-type |
Display Type | LCD |
SpO2 Display Range | 0%-100% |
SpO2 Measurement Range | 70%-100% |
Pulse Rate Display Range | 0-240bpm |
Pulse Rate Measurement Range | 30-240bpm |
Running Conditions | 5-40℃ |
Display Size | 22.7x17.8mm |
Humidity | 15%-93%RH |
Pressure | 700hPa-1060hPa |
SpO2 | Yes |
Pulse Rate | Yes |
Adjustable Brightness | No |
Display Modes | 2 |
Automatic Power-off | Yes |
Beeps | Yes |
Low Oxygen Content | Yes |
Bluetooth | No |
Power Source | 2“AAA”batteries |
Finger off Remind | Yes |
Power Dissipation | < 60mA |
The Data UPDATE Period | < 12S |
RED | Approx. 660nm Approx. 3.2mW |
IR | Approx. 905nm Approx. 2.4mW |
Unit Dimension | 60x32x32.9mm |
Unit Weight | Approx. 54g |
Packing | 1 pc / Gift box; 60 pcs / Carton |
Carton Dimensions | 36x22.5x35cm |
Carton Weight(G.W.) | 6.7kg |
• 24 years of OEM & ODM expertise.
• 3 manufacturing centers with 260,000㎡ automated facilities and 2000㎡ automated warehouses.
• 30+ production lines & 100+ patented innovations.
• ISO 13485, MDSAP, BSCI certified quality systems.
• Full customization for global brands, including Fortune 500 partners.

• WHX Dubai (formerly Arab Health), Dubai
• WHX Miami (formerly FIME), Miami, USA
• Hong Kong Electronics Fair, Hong Kong
• ABC Kids Expo, USA
• KIMES, Seoul, Korea
• MEDITEX Bangladesh, Dhaka
• Hospitalar, São Paulo, Brazil
• Canton Fair, China
• MEDICA, Düsseldorf, Germany
We are committed to meeting partners worldwide at leading international medical and consumer health exhibitions.

Q: How does the industry certification ensure reliable readings?
A: The certification confirms the device meets strict clinical accuracy standards, ensuring every SpO₂ and pulse rate measurement is dependable for informed health monitoring at home.
Q: Is it truly simple to operate for daily checks?
A: Yes. Its one-button design allows for instant measurement with no setup needed, and the large LCD screen clearly displays results in any lighting for quick, easy reading.
Q: What makes it a practical device for regular use on the go?
A: Its compact, lightweight design fits easily in a pocket or bag, and the intelligent power-saving feature with auto shut-off extends battery life, making it ideal for daily tracking anywhere.
For customized solutions or partnership inquiries, please contact us at marketing@sejoygroup.com to discuss your specific needs.
1. Before use, carefully read the manual.
2. Do not use the pulse oximeter:
-If you are allergic to rubber products.
-If the device or finger is damp.
-During MRI or CT scan.
-While taking a blood pressure measurement on the arm.
-Nail polish, dirty, coating fingers and false nails applied fingers.
-Fingers with anatomical changes, edemas, scars or burns.
-Too big finger: the width of finger is over than 20mm and the thickness is over than 15mm.
-Too small finger: the width of finger is less than 10mm and the thickness is less than 5mm.
-Minors under 18 years old.
-The environmental light changes strongly.
-Near flammable or explosive gas mixtures.
3. Extended use may cause pain for people with circulatory disorders. Do not use the pulse oximeter for longer than two hours on one finger.
4. Measurements are for your information only - they are no substitute for a medical examination. If an unexpected reading occurs, the operator can take several more measurements and consult a doctor.
5. Check the pulse oximeter regularly before use to ensure that there is no visible damage and the batteries are still sufficiently charged. In case of doubt, do not use the device and contact customer services or authorized retailer.
6. Do not use any additional parts that are not recommended by the manufacturer.
7. Any circumstances do not open or repair the device by yourself. Failure to comply will result in voiding of the warranty. For repairs, please contact customer services or authorized retailer.
8. Do not look directly inside the housing during the measurement. The red light and the invisible infrared light in the pulse oximeter are harmful to your eyes.
9. This device is not intended for use by people (including children) with restricted physical, sensory or mental skills or a lack of experience or a lack of knowledge, unless they are supervised by a person who has responsibility for their safety or they receive instructions from this person on how to use the device. Children should be supervised around the device to ensure they do not play with it.
10. If the unit has been stored at temperatures below 0℃, leave it in a warm place for about two hours before using it.
11. If the unit has been stored at temperatures above 40 , leave it in a cool place for about two hours before using it.
12. The displays for the pulse bar does not allow the strength of the pulse or circulation to be evaluated at the measurement site. Rather, they are exclusively used to display the current visual signal variation at the measurement site and do not enable diagnostics for the pulse.
13. Operation of the fingertip pulse oximeter may be affected by the use of an electrosurgical unit (ESU).
14. Follow local ordinances and recycling instructions regarding disposal or recycling or the device and device components, including batteries.
15. This equipment complies with IEC 60601-1-2 for electromagnetic compatibility for medical electrical equipment and systems. In healthcare center or other environment, their radio transmission equipment and electromagnetic interference may affect the performance of the oximeter.
16. This equipment is not intended for use during patient transport outside the healthcare facility.
17. When the signal is not stable, the reading may inaccurate. Please do not reference.
18. Portable and mobile RF communications equipment can affect medical electrical equipment.
19. WARNING: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
20. WARNING: PORTABLE RF communications equipment (includeing peripherals such as antenna cables and external antennas) should be used no closer than 30cm (12 inches) to any part of Fingertip Pulse Oximeter, including cables specified by the MANUFACTURER. Otherwise, degradation of the performance of this equipment could result.
21. Any serious incident that has occurred in relation to the device should be reported to the manufacture and the competent authority of the Member State in which the user and/or patient is established.